Humidity
Designed to meet or exceed the following:
Bellcore GR-63, Section 4.1
Operating: 15%-90% (non-condensing) at 55°C (131°F)
Non-Operating: 5%-95% (non-condensing) at 40°C (104°F)
Altitude
Designed to meet or exceed the following:
Operating: 4000 m (13123 ft)
Non-operating: 15000 m (49212 ft)
Vibration
Designed to meet or exceed the following:
Bellcore GR-63, Section 4.4
ETSI EN 300 019-2-3
Operating: Sinusoidal 1.0G (5-100Hz), 0.2G (100-200Hz), each axis
Packaged: Random 0.89Grms (5-200Hz), each axis
Shock
Designed to meet or exceed the following:
DIN/IEC 60068-2-27
Bellcore GR-63, Section 4.3
ETSI EN 300 019-2-3
Operating: 3G, half-sine 11ms, each axis
Packaged: 18G, half-sine 6ms, each axis
Safety
Designed to meet or exceed the following:
CB report to IEC 60950-1, complies with EN/CSA/ UL 60950-1
EMC
Designed to meet or exceed the following:
FCC 47 CFR Part 15, Subpart B
EN55022, EN55024
EN 300 386
Reliability
MTBF: > 384,000 hours @ 40°C/104°F (Telcordia SR-332, Issue 1)
HW Monitoring
LEDs
ATCA LEDs:
4 LEDs ("Ready for Hot Swap", "Out of Service", "Healthy", "Activity")
Board Management
based on IPMI 1.5
FRU Management
Sensors (Voltage, Current, Temperature, Fuse)
Status and Alerting
Hot Swap Management for Base Board and AMC
Electronic Keying of Base and Fabric Interfaces and AMC ports
Local SEL
Table 1-2: AT8404 Main Specifications
AT8404 SPECIFICATIONS