Table 4-58:Power State sensor
Table 4-59:FRU MngtPwr Fail sensor
Table 4-60:Jumper Status sensor
Event/Reading Type Code Sensor Type Sensor Specific Offset Event Trigger
6fh
Standard IPMI
sensor specific
D1h
Kontron OEM Power state
sensor
00h Power ON
01h Power OFF
02h Power ON Request
03h Power ON In Progress
04h Power OFF Request
05h Graceful Power OFF Request
06h Power OFF In Progress
07h Synchronise Graceful Power OFF
08h Power OFF Now Request
Event/Reading Type Code Sensor Type Sensor Specific Offset Event Trigger
03h
Standard IPMI
Discrete
D2h
OEM Kontron FRU Manage-
ment Power Fail sensor
00h
01h
State Asserted /
State Deasserted
Event Data 2:
undefined
Event Data 3:FRU ID
Event/Reading Type Code Sensor Type Sensor Specific Offset Event Trigger
6fh
Standard IPMI
sensor specific
D3h
Kontron OEM Jumper Status
Sensor
00h Jumper 00 Present ( JP1: 1-2 )
01h Jumper 01 Present ( JP1: 3-4 )
02h Jumper 02 Present ( JP1: 5-6 )
03h Jumper 03 Present ( JP1: 7-8 )
04h Jumper 04 Present ( JP1: 9-10 )
05h Jumper 05 Present ( JP1: 11-12 )
06h Jumper 06 Present ( JP1: 13-14 )
07h Jumper 07 Present ( JP2: 1-2 )
08h Jumper 08 Present ( JP2: 3-4 )
09h Jumper 09 Present ( JP2: 5-6 )
0Ah Jumper 10 Present ( JP2: 7-8 )
0Bh Jumper 11 Present ( JP2: 9-10 )
0Ch Jumper 12 Present ( JP2: 11-12 )
0Dh Jumper 13 Present ( JP2: 13-14 )
0Eh Unused