Manual
66 AT8242
www.kontron.com
Table 4-51:POST Value sensor
Table 4-52:Diag Status sensor
Table 4-53:Fwupg Status sensor
Table 4-54:FRU Over Icc sensor
Table 4-55:FRU Sensor Error sensor
Event/Reading Type Code Sensor Type Sensor Specific Offset Event Trigger
6Fh
Standard IPMI
sensor specific
C6h
OEM Kontron
POST Code Value
00h to 07h
POST code LOW byte value, no event gener-
ated on these offsets
14h
POST Code Error Event Trigger
Event Data 2: POST Low Nibble
Event Data 3: POST High Nibble
Event/Reading Type Code Sensor Type Sensor Specific Offset Event Trigger
6Fh
Standard IPMI
sensor specific
C9h
OEM Diagnostic Status
00h Diagnostic Started
01h Diagnostic PASSED
02h Diagnostic FAILED
Event/Reading Type Code Sensor Type Sensor Specific Offset Event Trigger
6Fh
Standard IPMI
sensor specific
CAh
OEM System Firmware
Upgrade Status
00h Upgrade Started
01h Upgrade PASSED
02h Upgrade FAILED
Event/Reading Type Code Sensor Type Sensor Specific Offset Event Trigger
03h
Standard IPMI
Discrete
CBh
OEM Kontron FRU Over Cur-
rent
00h
01h
State Asserted /
State Deasserted
Event Data 2:
00h: Over Current on Management power.
01h: Over Current on Payload power.
Event Data 3:FRU ID
Event/Reading Type Code Sensor Type Sensor Specific Offset Event Trigger
03h
Standard IPMI
Discrete
CCh
OEM Kontron FRU Sensor
Error
00h
01h
State Asserted /
State Deasserted
Event Data 2:
undefined
Event Data 3:FRU ID