Manual
50 AT8242
www.kontron.com
4.3.3.2 Carrier Activation and Carrier Information Tables
Each NPU engine is seen as a virtual AMC, with its own power and reset domain. Even though they are not
physically extractable, relevant carrier information records are present in FRU data as to insure proper
compatibility with the AMC.0 R2.0 specification.
Table 4-23:Carrier Activation and Current Management
Link Descriptor 00132F42h
Link Grouping ID (Bits 31-24) 00h: Single-channel link
Link Type Extension (Bits 23-20) 1h: Fixed 40GBASE-KR4
Link Class (bits 19-16) 3h: 10.3125Gbd Signaling Link Class
Link Type (Bits 15-12) 2h: PICMG 3.1 Ethernet Fabric Interface
Link Designator (Bits 11-0) F42h: Fabric Interface, Channel 2, Port 0, 1, 2, 3
Link Descriptor 00032142h
Link Grouping ID (Bits 31-24) 00h: Single-channel link
Link Type Extension (Bits 23-20) 0h: Fixed 10GBASE-KR
Link Class (bits 19-16) 3h: 10.3125Gbd Signaling Link Class
Link Type (Bits 15-12) 2h: PICMG 3.1 Ethernet Fabric Interface
Link Designator (Bits 11-0) 142h: Fabric Interface, Channel 2, Port 0
Field Value
Record Type ID C0h
Record Format Version 02h
Record Length *Calculated
Record Checksum *Calculated
Header Checksum *Calculated
Manufacturer ID 00315Ah (PICMG Record ID)
PICMG Record ID
17h (Carrier Activation and Current Management
Record)
Record Format Version 00h
Maximum Internal Current 50h (8 Amps at 12V => 96 Watts)
Allowance for Module Activation
Readiness
02h
Module Activation and Power
Descriptor Count
02h
Carrier Activation and Power
Descriptor
7A28FFh
Local IPMB-L Address 7Ah
Maximum Module Current 28h (4 Amps at 12V => 48 Watts)
Reserved FFh
Field Value