Manual

46 AT8242
www.kontron.com
4.3.2.2 IPMC Health Indicator Sensor Aggregation
The following table shows the sensors involved in the Health Sensor Aggregation.
Table 4-19:IPMC Health Indicator Sensor Aggregation
59 IPMC SEL State Discrete
Specifies SEL status (Cleared/Almost Full/Full)
Sensor type = 10h Event Logging Disable
Event Reading type code = 6Fh Sensor specific, offset 2,4,5 are used
See IPMI v1.5 table 36.3, Sensor type code 10h for sensor definition
60 Jumper Status Discrete
Reflects on-board jumper presence
Sensor type = D3h OEM (Kontron OEM Jumper Status)
Event Reading type code = 6Fh Sensor specific, offsets 0 to 14 are used
See OEM table, Sensor type code D3h for sensor definition
61 IPMI Info-1 Discrete
Internal Management Controller firmware diagnostic
Sensor type = C0h Kontron OEM Firmware Info
Event Reading type code = 70h Kontron OEM Internal Diagnostic
See OEM table, Sensor type code C0h and Event/Reading type code 70h for
sensor definition
62 IPMI Info-2 Discrete
Internal Management Controller firmware diagnostic
Sensor type = C0h Kontron OEM Firmware Info
Event Reading type code = 75h Kontron OEM Internal Diagnostic
See OEM table, Sensor type code C0h and Event/Reading type code 75h for
sensor definition
IPMI Sensor ID Sensor Name
5 Temp Inlet
6 Temp Outlet
7 Temp IPMC
8 Temp Switch
9 Temp SO-DIMM
10 Brd Input Power
11 RTM Power
12 Vcc +12V SUS
13 Vcc +5V SUS
14 Vcc +3.3V SUS
15 Vcc +2.5V SUS
16 Vcc +1.5V SUS
17 Vcc +1.2V SUS
18 Vcc +0.75V SUS
19 Vcc +1.2V Early
20 Vcc +5V
21 Vcc +2.5V
22 Vcc +1.1V
23 Vcc +1.05V
ID Sensor Name Sensor Class Description (Sensor Type, Event trigger)