Manual
45 AT8242
www.kontron.com
47 FRU3 IPMBL State Discrete
IPMB-L branch from FRU3 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific, offset 2 and 3 are used
See OEM table, Sensor type code C3h for sensor definition
48 FRU Over Icc Discrete
FRU Over Current Sensor
Sensor type = CBh OEM (Kontron OEM FRU Over Current)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CBh for sensor definition
49 FRU Sensor Error Discrete
FRU Error during external FRU Sensor discovery
Sensor type = CCh OEM (Kontron OEM FRU sensor error)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CCh for sensor definition
50 FRU Pwr Denied Discrete
FRU Power Denial Detection
Sensor type = CDh OEM (Kontron FRU Power denied)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CDh for sensor definition
51 FRU MngtPwr Fail Discrete
FRU Management Power Fail
Sensor type = D2h OEM (Kontron FRU Management Power Fail)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code D2h for sensor definition
52 FRU0 Agent Discrete
FRU Information Agent - FRU0 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition
53 FRU1 Agent Discrete
FRU Information Agent - FRU1 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition
54 FRU2 Agent Discrete
FRU Information Agent - FRU2 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition
55 FRU3 Agent Discrete
FRU Information Agent - FRU3 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition
56 EventRcv ComLost Discrete
Detects communication with the event receiver (ShMC) has been lost
Sensor type = 1Bh Cable/Interconnect
Event Reading type code = 03h Digital Discrete
See IPMI v1.5 table 36.2 and table 36.3 for sensor definition
57 IPMC Reboot Discrete
IPMC reboot detection
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See IPMI v1.5 table 36.3, Sensor type code 24h for sensor definition
58 IPMC Storage Err Discrete
Management sub-system health: non volatile memory error
Sensor type = 28h Management Subsystem Health
Event Reading type code = 6Fh Sensor specific, offset 1 is used
See IPMI v1.5 table 36.3, Sensor type code 28h for sensor definition
ID Sensor Name Sensor Class Description (Sensor Type, Event trigger)