Manual
44 AT8242
www.kontron.com
35 Board Reset Discrete
Board reset type and sources
Sensor type = CFh OEM (Kontron Reset Sensor)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM sensor table, Sensor type code CFh for sensor definition
36 POST Value Discrete
Show current postcode value
Sensor type = C6h OEM (Kontron POST value sensor)
Event Reading type code = 6Fh Sensor specific, offset 0 to 7 and 14 are used
See OEM sensor table, Sensor type code C6h for sensor definition
37 POST Error Discrete
CPU Power On Self Test Error
Sensor type = 0Fh System Firmware Progress
Event Reading type code = 6Fh Sensor specific, offset 0 is used
See IPMI v1.5 table 36.3, Sensor type code 0Fh for sensor definition
38 Boot Error Discrete
Boot Error
Sensor Type = 1Eh Boot Error
Reading type code = 6Fh Sensor Specific, offset 0 is used
See IPMI v1.5 table 36.3, Sensor type code 1Eh for sensor definition
39 Diag Status Discrete
Diagnostic Status
Sensor Type = C9h OEM (Kontron Diagnostic Status Sensor)
Event Reading type code = 6Fh Sensor Specific, offset 0 to 2 are used
See OEM sensor table, Sensor type code C9h for sensor definition
40 Fwupg Status Discrete
System Firmware Update Status
Sensor type = CAh OEM (Kontron OEM System firmware upgrade Status)
Event Reading type code = 6Fh Sensor specific, offset 0 to 2 are used
See OEM table, Sensor type code CAh for sensor definition
41 IPMI Watchdog Discrete
IPMI Watchdog (payload watchdog)
Sensor type = 23h Watchdog 2
Event Reading type code = 6Fh Sensor specific, offset 0,1,2,3,8 are used
See IPMI v1.5 table 36.3, Sensor type code 23h for sensor definition
42 Ver Change IPMC Discrete
IPMC Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v1.5 table 36.3, Sensor type code 2Bh for sensor definition
43 Ver Change FPGA Discrete
FPGA Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v1.5 table 36.3, Sensor type code 2Bh for sensor definition
44 Health Error Discrete
General health status, Aggregation of critical sensors. This list is flexible and
could be adjusted based on customer requirements.
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See IPMI v1.5 table 36.3, Sensor type code 24h for sensor definition
45 IPMB0 Link State Discrete
IPMB-0 fault detection sensor
Sensor type = F1h PICMG Physical IPMB-0
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-69, “Physical IPMB-0 event message”
46 FRU0 IPMBL State Discrete
IPMB-L branch from FRU0 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific, offset 2 and 3 are used
See OEM table, Sensor type code C3h for sensor definition
ID Sensor Name Sensor Class Description (Sensor Type, Event trigger)