Manual
34 AT8242
www.kontron.com
Table 4-6:Chassis Device Supported Commands for IPMC
Table 4-7:Event Supported Commands for IPMC
Table 4-8:PEF and Alerting Supported Commands for IPMC
IPMI Spec. section NetFn CMD IPMI BMC req. Carrier IPMC
req.
Kontron support
on IPMC
Chassis Device
Commands
O O
Get Chassis Capabilities 28.1 Chassis 00h M O Yes
Get Chassis Status 28.2 Chassis 01h O/M O Yes
Chassis Control 28.3 Chassis 02h O/M O Yes
Chassis Reset 28.4 Chassis 03h O O No
Chassis Identify 28.5 Chassis 04h O O No
Set Chassis Capabilities 28.7 Chassis 05h O O No
Set Power Restore Policy 28.8 Chassis 06h O O No
Get System Restart
Cause
28.11 Chassis 07h O O No
Set System Boot Options 28.12 Chassis 08h O O No
Get System Boot Options 28.13 Chassis 09h O O No
Get POH Counter 22.12 Chassis 0Fh O O No
IPMI Spec. section NetFn CMD IPMI BMC req. Carrier IPMC
req.
Kontron support
on IPMC
Event Commands M M
Set Event Receiver 29.1 S/E 01h M M Yes
Get Event Receiver 29.2 S/E 02h M M Yes
Platform Event 29.3 S/E 03h M M Yes
IPMI Spec. section NetFn CMD IPMI BMC req. Carrier IPMC
req.
Kontron support
on IPMC
PEF and Alerting
Commands
O O
Get PEF Capabilities 30.1 S/E 10h M M Yes
Arm PEF Postpone Timer 30.2 S/E 11h M M Yes
Set PEF Configuration
Parameters
30.3 S/E 12h M M Yes
Get PEF Configuration
Parameters
30.4 S/E 13h M M Yes