User Manual

55 AT8060
www.kontron.com
95 Ver Change IPMC Discrete
IPMC Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v2.0 table 42-3, Sensor type code 2Bh for sensor
definition
96 Ver Change FPGA Discrete
FPGA Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v2.0 table 42-3, Sensor type code 2B for sensor
definition
97 Ver Change BIOS Discrete
BIOS Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v2.0 table 42-3, Sensor type code 2Bh for sensor
definition
98 EventRcv ComLost Discrete
Detects communication with the event receiver (ShMc)
Sensor type = 1Bh Cable/Interconnect
Event Reading type code = 03h Digital Discrete
See IPMI v1.5 table 36.2 and table 36.3 for sensor definition
99 IPMC Reboot Discrete
IPMC reboot detection
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete
Only offset 0,1 are usedà
See IPMI v2.0 table 42-3, Sensor type code 24h for sensor
definition
100 IPMC Storage Err Discrete
Management sub-system health: non volatile memory error
Sensor type = 28h Management Subsystem Health
Event Reading type code = 6Fh Sensor specific
Only only offset 1 is used
See IPMI v2.0 table 42-3, Sensor type code 28h for sensor
definition
101 IPMC SEL State Discrete
Specify if the status of the SEL (Cleared/Almost Full/Full)
Sensor type = 10h Event Logging Disable
Event Reading type code = 6Fh Sensor specific
Only offset 2,4,5 are used
See IPMI v2.0 table 42-3, Sensor type code 10h (Event Log
Disable) for sensor definition