User Manual
42 AT8060
www.kontron.com
4.6.2.1 IPMC Sensors
Table 4-18: IPMC Sensors
0 FRU0 Hot Swap Discrete
ATCA Board FRU Hot Swap Sensor for FRU 0 (Front Board)
Sensor type code = F0h PICMG Hot Swap
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”
1 FRU1 Hot Swap Discrete
ATCA Board FRU Hot Swap Sensor for FRU 1 (AMC B1)
Available only when AMC is inserted
Sensor type code = F0h PICMG Hot Swap
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”
2 FRU2 Hot Swap Discrete
ATCA Board FRU Hot Swap Sensor for FRU 2 (RTM)
Available only when RTM is inserted
Sensor type code = F0h PICMG Hot Swap
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”
3 FRU3 Hot Swap Discrete
ATCA Board FRU Hot Swap Sensor for FRU 3 (RTM Disk 1)
Available only when RTM and 1 disk is inserted
Sensor type code = F0h PICMG Hot Swap
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”
4 FRU4 Hot Swap Discrete
ATCA Board FRU Hot Swap Sensor for FRU 4 (RTM Disk 2)
Available only when RTM and 2 disks are inserted
Sensor type code = F0h PICMG Hot Swap
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”
5 FRU0 Reconfig Discrete
Sensor Population Change on Carrier
Sensor type = 12h System Event
Event Reading type code = 6Fh Sensor specific, only offset 0 is
used
See AMC.0 R2.0 for event trigger
See IPMI v2.0 table 42-3, Sensor type code 12h for sensor
definition
6 Temp Board Inlet Threshold
Board Inlet Temperature (Degrees)
Sensor type = 01h temperature
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event