Manual

56 AT8050
www.kontron.com
4.3.2.2 IPMC Health Indicator Sensor Aggregation
The following table shows the sensors involved in the health sensor aggregation.
Table 4-18: IPMC Health Indicator Sensor Aggregation Table
100 ME Availability Discrete
Provides status on the chipset Management Engine
Sensor type = 28h Management Subsystem Health
Event Reading type code = 0Ah Generic Discrete, offset 2,6,8 are used
see IPMI v1.5 table 36.2, event reading type code 0Ah for sensor definition
101 Jumper Status Discrete
Reflects on-board jumper presence
Sensor type = D3h OEM (Kontron OEM Jumper Status)
Event Reading type code = 6Fh Sensor specific, offsets 0 to 14 are used
-see OEM table, Sensor type code D3h (Kontron OEM Jumper Status) for sensor
definition
102 IPMI Info-1 Discrete
Internal Management Controller firmware diagnostic Sensor type = C0h Kontron
OEM Firmware Info Event Reading type code = 70h Kontron OEM Internal
Diagnostic -see OEM table, Sensor type code C0h (Kontron OEM Firmware Info)
for sensor definition and Event/Reading type code 70h (ontron OEM Internal
Diagnostic)
103 IPMI Info-2 Discrete
Internal Management Controller firmware diagnostic Sensor type = C0h Kontron
OEM Firmware Info Event Reading type code = 75h Kontron OEM Internal
Diagnostic -see OEM table, Sensor type code C0h (Kontron OEM Firmware Info)
for sensor definition and Event/Reading type code 70h (ontron OEM Internal
Diagnostic)
IPMI sensor ID Sensor Name
5 Temp -48V A Feed
6 Temp -48V B Feed
7 Temp Mez 12V Out
8 Temp VDDQ
9 Temp Vcore
10 Temp IPMC
11 Temp IOH
12 Temp ICH
13 Temp Mngt Lan
14 Temp BI Lan
15 Temp FI Lan
16 Temp Bay Inlet
17 Temp CPU
18 Temp DIMM#1
19 Temp DIMM#2
20 Temp DIMM#3
21 Temp DIMM#4
22 Temp DIMM#5
23 Temp DIMM#6
25 Brd Input Power
ID Sensor Name Sensor Class Description (Sensor Type, Event trigger)