Manual
55 AT8050
www.kontron.com
87 FRU Over Icc Discrete
FRU Over Current Sensor Sensor type = CBh OEM (Kontron OEM FRU Over Current)
Event Reading type code = 03h Digital Discrete offset 0,1 are used, -see OEM
table, Sensor type code CBh (Kontron OEM FRU Overcurrent) for sensor
definition
88 FRU Sensor Error Discrete
FRU Error during external FRU Sensor discovery Sensor type = CCh OEM (Kontron
OEM FRU sensor error) Event Reading type code = 03h Digital Discrete offset 0,1
are used, -see OEM table, Sensor type code CCh (Kontron OEM FRU sensor error)
for sensor definition
89 FRU Pwr Denied Discrete
FRU Power Denial Detection Sensor type = CDh OEM (Kontron FRU Power denied)
Event Reading type code = 03h Digital Discrete offset 0,1 are used -see OEM
table, Sensor type code CDh (Kontron OEM FRU Power Denied) for sensor
definition
90 FRU MngtPwr Fail Discrete
FRU Management Power Fail Sensor type = D2h OEM (Kontron FRU Management
Power Fail) Event Reading type code = 03h Digital Discrete offset 0,1 are used -
see OEM table, Sensor type code D2h (Kontron OEM FRU Management Power
Fail) for sensor definition
91 FRU0 Agent Discrete
FRU Information Agent - FRU0 Data Error Detection Sensor type = C5h OEM
(Kontron FRU Info Agent) Event Reading type code = 0Ah Generic Discrete,
offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
92 FRU1 Agent Discrete
FRU Information Agent - FRU1 Data Error Detection Sensor type = C5h OEM
(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,
offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
93 FRU2 Agent Discrete
FRU Information Agent - FRU2 Data Error Detection Sensor type = C5h OEM
(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,
offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
94
FRU3 Agent Discrete
FRU Information Agent - FRU3 Data Error Detection Sensor type = C5h OEM
(Kontron FRU Info Agent), Event Reading type code = 0Ah Generic Discrete,
offset 6,8 are used -see OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
95 EventRcv ComLost Discrete
Detects communication with the event receiver (ShMc) has been lost Sensor
type = 1Bh Cable/Interconnect, Event Reading type code = 03h Digital Discrete -
see IPMI v1.5 table 36.2 and table 36.3 for sensor definition
96 IPMC Reboot Discrete
IPMC reboot detection Sensor type = 24h Platform Alert, Event Reading type
code = 03h Digital Discrete offset 0,1 are used -see IPMI v1.5 table 36.3, Sensor
type code 24h for sensor definition
97 IPMC FwUp Discrete
Kontron OEM IPMC firmware upgrade Status Sensor type = C7h OEM (Kontron
OEM MC firmware upgrade Status) Event Reading type code = 6Fh Sensor
specific, offset 0,1 are used -see OEM table, Sensor type code C7h (Kontron OEM
MC firmware upgrade Status) for sensor definition
98 IPMC Storage Err Discrete
Management sub-system health: non volatile memory error. Sensor type = 28h
Management Subsystem Health Event Reading type code = 6Fh Sensor specific,
only offset 1 is used, -see IPMI v1.5 table 36.3, Sensor type code 28h for sensor
definition
99 IPMC SEL State Discrete
Specify if the status of the SEL (Cleared/Almost Full/Full) Sensor type = 10h
Event Logging Disable Event Reading type code = 6Fh Sensor specific, only
offset 2,4,5 are used, -see IPMI v1.5 table 36.3, Sensor type code 10h (Event
Log Disable) for sensor definition
ID Sensor Name Sensor Class Description (Sensor Type, Event trigger)