Manual
22 AT8050
www.kontron.com
2.9.4.6 AMC to Fabric Interface and Management to RTM Configuration
Figure 2-8: AMC to Fabric Interface and Management to RTM
Note:
- The AMC must be able to support GbE on ports 8-11
- Connection from AMC to the Fabric Interface is either PICMG3.1 option 2 (2x1GbE) or PICMG3.1
option 1 (1xGbE).
BIOS Settings:
1) System Management --> OEM E-Keying Configuration --> Management LAN Setting: RTM
2) System Management --> OEM E-Keying Configuration --> AMC P8-11 Setting: Fabric Interface
In this configuration, it is not possible to boot from the Fabric Interface
MGNT
82576EB
Front
2x RJ-45
AMC**
BI
82576EB
RTM
Ports 0-1
Ports 0-1
Fabric Interface
Channel 1
Ports 0-1
Base Interface
Channel 1
GbE
Fabric Interface
Channel 2
Ports 0-1
82599EB
10 GbE
Out
p
ut 1
Out
p
ut 2
Base Interface
Channel 2
Copper
1
2
AMC
AMC
Ports 9
,
11
Ports 0-1
Ports 8
,
10