Datasheet
2
Konica Minolta bizhub C364e/C284e/C224e
Specification & Installation Guide
bizhub C364e/C284e/C224e Specifications continued
Print speed (ppm)*:
continued
Color/B&W (double sided/plain paper):
Size C364e C284e C224e
11"x17" 18 14 14
8.5"x14" 20 16 16
8.5"x11"P 36 28 22
8.5"x11"L 25 20 20
5.5"x8.5"L 36 28 22
8"x13"L 20 16 16
*Using 1st Tray
Magnification
ratios
1.0 (full size: 1.00+_0.5% or less)
Enlarge: 121.4%, 129.4%, 154.5%, 200%
Reduce: 78.5%, 73.3%, 64.7%, 50.0%
Minimal: 93%
Stored Zoom Ratios: 3
"Minimal" zoom ratio (90% to 99.9%)
Multiple copies 1 to 9,999 sheets
Density control Copy Density: Manual Density Adjustment
(9 Levels); Background Density: Automatic
and Manual Density Adjustments (9 levels)
Power
requirements
120V, 12 A, 60 Hz
Power
consumption
1.5 kW or less
TEC Value
C364e: 2.12 kWh
C284e: 1.65 kWh
C224e: 1.25 kWh
Dimensions
(with control panel)
24.2" (W)x27" (D) x31" (H)
Space requirements* 36.9" (W)x47.8" (D) x 30.7" (H)
Memory (available
hard disk space)
2 GB, (250 GB HDD) (std); 2 GB (opt).
Weight Approx. 185.18 lb.
* The indicated space requirements represent the space required to pull out
thepaper tray and the tray extension of the bypass tray and with the ADF open.
Duty Cycle
Up to C364e: 125,000, C284e: 100,000, C224e: 80,000.
Maximum monthly copy/print volume supported under
standard vendor supplied service. Defines the upper
end of the expected customer volume for the device.
Customers should consider multiple machines if average
monthly volume approaches duty cycle on continual basis.
Environmental Requirements
Temperature 50° F to 86° F
Humidity 15% to 85%
Noise during operation (BW/Color) C364e: 71.6 dB/71.8 dB
C284e: 68.8 dB/69.4 dB
C224e: 66.7 dB/67.6 dB
Noise during feeder operation
(FS-534/FS-533)
C364e: 69.2 dB or less
C284e: 68.0 dB or less
C224e: 67.6 dB or less
Noise during standby 40.5 dB or less
Ozone emission Color: 3.0 mg/h
Color: 1.5 mg/h
Electrical Requirements
Line Options Dedicated NEMA Diagram for 5-15R
Voltage: 110 V/120
to 127 V/220
to 240 V AC
Amperage 12 A
Cycles 60 Hz
NEMA Part No: 5-15R
Cord Length 6.6 ft.
Note: The main electrical outlet must be located within 6.6 feet from the right rear
corner of the bizhub C364e/C284e/C224e main unit.