User Manual
ii 
Operation of Safety Plug  
Your air conditioner is supplied with a Leakage-Current Detection and Interruption (LCDI) safety 
plug. This device provides protection to reduce the risk of fire due to arcing faults in the power 
supply cord. Before using your air conditioner, follow the instructions below to ensure that the 
LCDI plug is working properly: 
1. Plug the power cord into a grounded outlet. 
2. Press the TEST button on the LCDI plug. This should trip the plug and cut the power to the air 
conditioner. If the plug does not trip and you are able to turn on the unit, please contact 
EdgeStar support. 
DO NOT USE YOUR AIR CONDITIONER IF THE TEST FAILS. 
3. Press the RESET button to start using your air conditioner. 
Note: Electrical products should not be disposed of with household waste. Please contact your 
local recycling center for more information on how to recycle electronic waste. 
Notes: 
  Always make sure the “Reset” button is pushed in for proper operation. 
  The power supply cord with LCDI plug must be replaced if it fails to reset. 
  Do not use the TEST and RESET buttons as an ON/OFF switch. 
  Please refer to the Specifications section of this document for additional information on the 
correct LCDI Plug Type for your model. 