Company: Numo Manufacturing
Test Report #
16H-00122
Recipient: Rebecca Williams Date of Issue: January 14, 2016
Recipient Email: rwilliams@numomfg.com Pages: Page 2 of 12
cc to Email: - Date Received: January 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374
ansecogroup.com
AT-1500
V
er.05CS-HK-RE005
DETAILED RESULTS:
CPSIA Section 101, Total Lead in Substrate Materials
Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance
with the above referenced regulation.
[Referenced Test Method: CPSC-CH-E1001-08.2 (Metal) and/or CPSC-CH-E1002-08.2 (Non-Metal)]
Specimen No. 1 2 3 4+5+6 7+8+9 Limit
Test Item
Result
(ppm)
Result
(ppm)
Result
(ppm)
Result
(ppm)
Result
(ppm)
Total
(ppm)
Total Pb ND ND ND ND ND 100
Conclusion PASS PASS PASS PASS PASS
Specimen No. 10+11+12 13+14+15 16+17+18 19+20+21 22+23+24 Limit
Test Item
Result
(ppm)
Result
(ppm)
Result
(ppm)
Result
(ppm)
Result
(ppm)
Total
(ppm)
Total Pb ND ND ND ND ND 100
Conclusion PASS PASS PASS PASS PASS
Specimen No. 25+26+27 --- --- --- --- Limit
Test Item
Result
(ppm)
Result
(ppm)
Result
(ppm)
Result
(ppm)
Result
(ppm)
Total
(ppm)
Total Pb ND --- --- --- --- 100
Conclusion PASS --- --- --- ---
Note:
Pb = Lead
ppm (Parts per million) = mg/kg (Milligrams per kilogram)
LT = Less than
ND = Not detected (Reporting Limit = 20ppm)
Composite results are based on specimen of least mass resulting in highest potential concentration.