Specifications

1-1/4"
Notes
Required Electrical Service
Measure your actual product for rough-in details.
Three dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD).
Install this product according to the installation
instructions.
The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.
120 V, 15 A, 60 HzPump, Heater:
120 V, 15 A, 60 HzHeater:
120 V, 15 A, 60 HzBlower:
Provide one grounded electrical outlet within 24"
(610 mm) of each component.
Technical Information
All product dimensions are nominal.
Remote blower installation kit is available for
relocating the blower. Provide access for servicing
the blower.
Three-wall alcoveInstallation:
RightDrain location:
Do not relocate or alter the PVC tee or coiled
flexible tubing connected to the blower. Follow
the blower relocation instructions exactly.
50-3/8" x 19-5/8" (1280 mm x 498 mm)Basin area, bottom:
57-5/16" x 24-1/16" (1456 mm x 611 mm)Basin area, top:
165 lbs (74.8 kg)Weight:
ADA compliant when installed to the specific
requirements of these regulations.
50 lbs/ft² (244.1 kg/m²)Minimum floor load:
15-5/16" (389 mm)Water depth:
66 gal (249.8 L)Water capacity:
Pump: 120 V, 7 A, 60 Hz
Heater: 120 V, 5 A, 60 Hz
Electrical component
rating:
Heater: 120 V, 12 A, 60 Hz
Blower: 120 V, 10 A, 60 Hz
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
4-25-2019 19:20 - US
Archer
®
apron whirlpool + Heated BubbleMassage
air bath
K-1949-XGHRA