Installation Guide

Troubleshooting (cont.)
Solenoid Troubleshooting Table
Symptoms Probable Causes Recommended Action
1. Water leaking
from the solenoid
valve.
A. Hose
connections
are not
secure.
A. CAUTION: Risk of
personal injury or
product damage. Turn
off the main power and
water supply. Check all
connections. Make
adjustments as needed.
B. Internal leak. B. Replace the solenoid
valve assembly.
2. No audible click
when solenoid is
activated.
A. Loose
solenoid wire
connection.
A. Check solenoid wire
connection to the circuit
board.
B. Solenoid
valve is not
functioning.
B. Replace the solenoid
valve assembly.
Handle Switch Troubleshooting Table
Symptoms Probable Causes Recommended Action
1. Handle LED is lit
when the handle
is closed.
A. Valve
setscrew
needs
adjustment.
A. Refer to the Handle
LED Adjustment
section.
2. Handle does not
return to the
upright position.
A. Valve
setscrew
needs
adjustment.
A. Refer to the Handle
LED Adjustment
section.
3. Water does not
fully shut off.
A. Valve
setscrew
needs
adjustment.
A. Refer to the Handle
LED Adjustment
section.
4. Handle LED does
not illuminate
when the handle
is rotated open.
A. Loose handle
switch wire
connection.
A. Check handle switch
wire connection to the
circuit board.
B. Circuit board
is not
functioning
correctly.
B. Replace the cover
assembly.
1186051-2-F 18 Kohler Co.