Installation Guide

Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms Probable Causes Recommended Action
C. The hot
and/or cold
supply hose
is kinked or
twisted.
C. Confirm the supply
hoses are not kinked or
twisted. If coiled,
maintain an inside
diameter of 3 (76 mm).
D. The outlet
hose is
kinked.
D. Confirm the solenoid
valve is located within
7 (178 mm) to 8 (203
mm) from the faucet
base.
E. One or more
screens are
clogged.
E. Refer to the Cleaning
the Screens section.
F. Cracked
diaphragm.
F. Replace the solenoid
valve assembly.
3. Poor spray
pattern.
A. The spray
nozzles are
clogged.
A. Rub your finger over
the nozzles with water
running to dislodge
debris.
4. Circuit board LED
is not lit.
A. No power to
the circuit
board.
A. Check the power
supply connections to
the circuit board.
B. Power cord is
plugged into
a switched
outlet.
B. Plug the power cord
into an unswitched 120
VAC outlet (test the
outlet with a radio or
other device). Confirm
the circuit board LED
illuminates.
5. Water drip or
trickle when
faucet is not in
use.
A. Manual
override is
partially
engaged.
A. Turn the white manual
override clockwise until
it stops; then turn it
counterclockwise until
the water drip stops.
Kohler Co. 17 1186051-2-F