Remote Installation Sheet
Important Information
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. To reduce the risk of electrical shock, connect only to circuits
protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
WARNING: Risk of electric shock. A qualified electrician should make all electrical connections.
WARNING: Risk of electric shock. Disconnect power before servicing.
NOTICE: Follow all local plumbing and electrical codes.
Building materials and wiring should be routed away from the blower body and other heat-producing
components of the unit.
Install to permit access for servicing.
Product Information
Electrical Requirements
NOTE: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or
similarly qualified persons in order to avoid a hazard.
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD). The GFCI or RCD protects against line-to-ground shock hazard. Use a 120 V, 15 A, 50/60 Hz
dedicated service for the bath with airjets.
An equipment grounding terminal is provided in the field wiring compartment. To reduce the risk of electric
shock, this terminal must be connected to the grounding means provided in the electric supply panel with a
conductor equivalent in size to the circuit conductors supplying this equipment.
The electrical rating of the bath is printed on a label near the blower motor. You can also find the electrical
requirements from the installation guide packed with the bath and the specification sheet found on the
product page at www.kohler.com.
Product Notices
WARNING: Risk of personal injury or property damage. Unauthorized modification may cause
unsafe operation or effect performance of the bath with airjets. Do not relocate the blower motor,
or make other modifications to the bath system in the absence of kit or other published instructions,
as this could adversely affect the performance and safe operation of the product. Kohler Co. shall
not be liable under its warranty or otherwise for personal injury or damage caused by any such
unauthorized modification. Refer to the ″Before You Begin″ section for blower motor relocation
requirements, recommendations, and section coverage information.
NOTICE: Keep the area around the blower motor clean and free of debris. Ensure that the area around
the blower motor is free of sawdust, insulation, dirt, or other small loose debris. Such material could plug
the blower motor air ducts and reduce the air flow through the blower.
Connections and Service Access
NOTICE: Provide unrestricted service access to the blower motor. You must provide access for servicing
the blower motor and controls. The access must be located immediately next to the blower motor. Study
the roughing-in information.
Before installation, ensure that there is proper access to the blower motor and final connections. If the blower
1037564-2-D 2 Kohler Co.