Valve Trim Specification Sheet
Installation Notes
Install the product according to the installation guide.
Install the Rite-Temp valve according to the installation guide.
NOTICE: Risk of product damage. For K-2971-KS valve:
1-5/8″ (41 mm) screws (included) must be used. 2-3/8″ (60
mm) screws will damage the valve.
Avoid cross-flow conditions. Do not install a shut-off device on
either valve outlet.
Cap the shower outlet if the deck-mounted spout, diverter, or
handshower is connected to the spout outlet.
Install a 7″ (178 mm) to 18″ (457 mm) straight pipe or straight
tube with single elbow between the valve and the wall-mount
spout.
Ø 6-1/2"
(165 mm)
2-5/8"
(67 mm)
4-7/16"
(113 mm)
C
L of Valve Inlet
2-3/4" (70 mm) Thin Wall
3-1/2" (89 mm) Thick Wall
If over 3-1/2" (89 mm) and
up to 4-1/2" (114 mm),
use Deep Roughing-in kit.
Ø 6-1/2"
(165 mm)
4-7/16"
(113 mm)
L of Valve Inlet
2-3/4" (70 mm) Thin Wall
3-1/2" (89 mm) Thick Wall
If over 3-1/2" (89 mm) and
up to 4-1/2" (114 mm),
use Deep Roughing-in kit.
2-5/8"
(67 mm)
C
K-T8979-4
K-T8981-4
Product Diagram
TOOBITM RITE-TEMP
®
TOOBITM RITE-TEMP
®
VALVE TRIM
Page2of2
1194655-4-
A