Rough In Specification Sheet

Installation Notes
Install this product according to the installation guide.
Avoid cross-flow conditions. Do not install a shut-off device on
either valve outlet.
Cap the shower outlet if a deck-mount spout, diverter, or
handshower is connected to a spout outlet.
Install straight pipe or tube drop of 7 (178 mm) to 18
(457 mm) with single elbow between valve and wall-mount
spout. Refer to the installation instructions for proper
configuration of the connection between the valve and bath
spout.
Inlet Port
1/2" Cold
Inlet Port
1/2" Hot
Min Finished Wall
2-3/4" (70 mm)
Outlet Port
2-1/16"
(52 mm)
3-1/2" (89 mm)
2"
(51 mm)
4"
(102 mm)
-K
5-3/4"
(146 mm)
-KS
3-3/16"
(81 mm)
-PX
6-1/8"
(156 mm)
-PS
4"
(102 mm)
-UX
6-1/8"
(156 mm)
-US
6-5/8"
(168 mm)
-CX
8-1/2"
(216 mm)
-CS
1/2"-14 NPT or 5/8" ID
for 1/2" Nominal
Copper Tubing
A
AModel
Outlet Port
Max Finished Wall
Product Diagram