Datasheet

Parts No: KSM-200LM5R
9. Standard Inspection
10. Customer must check below clauses before using
1) Data word length = Max. 100msec
●●●
2) tpause = Min. 9msec
●●●
3) Duty(Σtburst /T ) = Max. 30%
●●●
4) tBurst = Min. 150usec
●●●
5) tGap = Min. 250usec
6) above (1)~(5) should be all meet and all remote control button should be operated properly.
11. Caution(When use and storage of this device)
KKC-QM-043-2(B) 5/8
REFERENCE
Among electrical characteristics, total quantity shall be inspected as below
9-1. Front distance between emitter and detector
standards.
suitable DATA FORMAT : : continuouse key ×: one key
NEC CODE SONY 12bit Matsushita Code
9-2. Current consumption
9-3. H level output voltage
9-4. L level output voltage
10-1. When this infrared remote control detecting unit shall be adopted for wireless remote control, please keep the following
Sharp Code RCMM JVC Code
Continuous Data communication don't support. (tpause = 0ms)
RC5 /RC6 SONY 15bit Mitsubishi Code
Toshiba Micom Code SONY 20bit Zenith Code
11-2. Store and use when there is no extreme humidity
11-3. Do not wash this device. Wipe the stains of diode side with a soft cloth.
You can use the solvent, ethylalcohol or methylalcohol or isopropylalcohol only.
11-4. The shield case shall be grounded on the PCB pattern. There are two cases, one is that shield case
10-2. If your condition doesn't meet the above statement, it might not operate properly.
10-3. We recommand minimum 30cm distance between RC-M and transmitter for normal operating.
If the distance between RC-M and Transmitter is too near, it might not respond.
11-1. Store and use where there is no force causing transformation or change in quality
11-6. Put decoupling device between Vcc and GND for reduce the noise from power supply line.
recommand Vcc-GND 47 and Vcc- 100. Decoupling device should be near receiver modules.
and GND pin are connected in the shiled case, the other is not connected in it.
If the receiver modules of shield case is not becoming ground connection, there is a possibility of being weak
in the EMI(Electronic Microwave Interperence) condition.
11-5. Solder pad within the condition of ratings. after soldering do not add extrorse force.