Scanner User's Guide
Table Of Contents
- 1 Introduction
- 2 Getting Started
- What’s in the box
- System requirements
- Installing the scanner
- Installing the Kodak Driver Software
- Connecting the power cord to the scanner
- Connecting the USB cable
- Attaching the output tray
- Turning on the scanner and finalizing Kodak Driver Software installation
- Installing application software
- Scanner components
- Locking the scanner
- 3 Using the Scanner
- Turning the scanner on and off
- Scanner positions
- Tilting the scanner body
- Adjusting the output tray
- Adjusting the input tray
- Adjusting the side guides
- Start and stop scanning
- Document preparation
- Verifying your scanner installation
- Viewing test images
- Understanding your scanning environment
- Smart touch functionality
- Scanning your documents
- 4 Image Processing
- Overview
- Starting the Scan Validation Tool
- Scan Validation Tool dialog box
- Using the TWAIN datasource
- The main Kodak Scanner window
- The Image Settingswindow
- Preview window
- Toolbar icons
- General tab
- Size tab
- Adjustments tab: black and white
- Adjustments tab: color or grayscale
- Enhancements tab
- Advanced options
- Content Settings tab
- Setting up automatic color detection - Example 1
- Setting up multiple images for each side of a document (dual stream) - Example 2
- Using different settings for each side of a document - Example 3
- Images for each side of a document (dual stream) - Example 4
- The Device Settings window
- The Diagnostics window
- Using the ISIS Driver
- 5 Maintenance
- Cleaning the scanner
- Opening the scanner cover
- Cleaning the rollers and transport
- Cleaning or replacing the separation module
- Replacing the separation module tires
- Cleaning or replacing the feed module
- Replacing the tires on the feed module
- Vacuuming the scanner
- Cleaning the imaging area
- Supplies and consumables
- Accessories
- 6 Troubleshooting
- Appendix A Specifications
- Appendix B Feature Map
- Appendix C Warranty - US and Canada only

A-61560 June 2006 81
Blank image detection — select the image size (KB), below which an
image is determined to be blank. Images with sizes less than the
number you select will not be created. If you use this option, you must
specify a blank image size for each image type (Binary, Gray and
Color) you want to delete. If you do not make an entry in these fields,
all images are kept.
Multi-feed Detection options
Length Detection this option can be enabled or disabled. The
default is disabled. If enabled, select the maximum length of the
document that can be scanned without a multi-feed being detected.
Length detection is used when scanning same-sized documents to
check for overlap. For example, if you are scanning 8.5 x 11-inch (A4)
documents in portrait mode, enter a value of 11.25 inches (28.57 cm) in
the Maximum Length field. The maximum value is 13.99 inches (35.56
cm).
• Auto Set: automatically sets the maximum length value to .50-inch
(1.27 cm) greater than the length of the currently selected page size.
Ultrasonic Detection — check this option to set multi-feed detection.
Sensitivity — controls how aggressively the scanner will work to
determine if more than one document is fed into the transport. Multi-
feeds are triggered by detecting air gaps between documents. This
allows multi-feed detection to be used with job sets containing
documents with mixed thicknesses. You may set the Multi-Feed
Detection to High, Medium or Low sensitivity.
• Low: the least aggressive setting and is less likely to detect labels,
poor quality, thick or wrinkled documents as multi-fed documents.
• Medium: use Medium sensitivity if your application has varying
document thickness or labels attached to the document. Depending
on the label material, most documents with labels should not be
detected as a multi-fed document.
• High: the most aggressive setting. This is a good setting to use if all
documents are similar in thickness to 20-lb. Bond paper.
Action — select an option of how you want to the scanner to perform if
it detects a multi-fed document.
• Beep and continue: if selected, the scanner will beep, display and
log the condition but continue to operate.
• End of Job: if selected, the scanner log the condition and stop the
feeder and transport (the scanner will be disabled).
Alarm - select this option if you want the scanner to make a sound
when a multi-feed is detected. You can click the Speaker icon to
display the Open dialog box. From the Open dialog box, select the
desired .wav file and click OK.
Calibrate — the Kodak i1200/i1300 Scanners automatically calibrate.
This option is available if a Kodak representative directs you to calibrate
the scanner using this option.