A-61628 December 2011 7-15
Replacing the USB 
connector 
The USB connector may need periodic replacement due to extended 
use which may be detectable due to repeated flash drive errors. Before 
changing the USB connector, be sure the USB flash drive itself is not 
defective.
Tools needed: Small Phillips Head screwdriver. 
1. Turn off the power to the Scan Station.
2. Unplug the power cord from the wall receptacle.
3. Be sure the output tray panel is open, then open the Scan Station 
cover.
4. Using a Phillips Head screwdriver, unfasten the screw that holds the 
USB connector cover in place and remove the cover.
5. Pull the USB connector out of position.
6. Slide the new USB connector into position.
7. Reinstall the USB connector cover and fasten the screw to hold the 
cover in place.
8. Close the Scan Station cover.
9. Plug the power cord into the wall outlet and turn on the Scan 
Station.