Operating Guide
12
CARE AND MAINTENANCE
WARNING
In order to avoid personal injury and the risk of re and electric shock, remove the battery pack before 
adjusting, inspecting, or cleaning the blower.
CLEANING
• Remove the battery pack.
• Brush or blow dust and debris out of the air vents using compressed air or a vacuum. Keep
 the air vents free of obstructions, sawdust, and wood chips. Do not spray, wash, or immerse the 
 air vents in water.
• Wipe off the housing and the plastic components using a moist, soft cloth. Do not use strong 
 solvents or detergents on the plastic housing or plastic components. Certain household cleaners 
 may cause damage, and may cause a shock hazard.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Unit will not blow.  1. Blocked tube. 1. Clear the blockage.
Motor fails to start
when switch trigger
is depressed.
 1. Battery is not secure.
2. Battery is not charged.
1. Ensure the battery is fully secure in 
 the battery compartment and the 
 battery release button locks into 
 place. 
 (Reference Page 10 of the 
 instruction manual).
2. Charge the battery pack according 
 to the instructions included with 
 your model.
Unit will not start.
 1. Defective power switch. 1. Return to place of purchase or re
 turn the unit to a repair center or 
 call customer service at 
 1-888-3KOBALT (1-888-356-2258).