SOCKET STRIPS DI-STRIP® Power Distribution Units also for France, Switzerland, USA 7
SOCKET STRIPS Socket Strips DI-STRIP® Strong points 7.3 DI-STRIP® TriplePower BladePower PizzaPower Classic Compact Protector Cleaner Safety Basic Safety Standard Master-Slave Combi GST18, 1-phase GST18, 3-phase 7.6 7.8 7.9 7.9 7.10 7.11 7.13 7.14 7.15 7.16 7.17 7.18 7.19 DOS00291 DOS00317 DOS00312 DI-STRIP® Euro Plug System 7.22 19’’ DI-STRIP® 7.25 For Switzerland 7.36 1 HU DI-STRIP® = 44.45 mm For France m 465 m m 483 m DI-STRIP® USA 7.39 DOS00365 Remote PDU DOS00721 7.
SOCKET STRIPS DI-STRIP® Strong points 1 Robust! Plug field protected with raised casing edges. 2 Stability High stability and torisional strength provided with closed sheet steel casing. 3 DOS00366 4 DOS20131 Electrical safety Full power to all connected consumers with full-length brass busbar. Shock hazard-proof and low contact resistance with double spring contacts. 19” installation Optimum use of space with 19” installation: - With low height, 1 HU (44.
SOCKET STRIPS Standard DIN 49 440 DI-STRIP® Classic Euro Plug System Page 7.9 / Page 7.41 / Page 7.42 - Socket spacing: 100 mm - With/without switch DOS00402 DI-STRIP® Compact - Socket spacing: 50 mm - With/without switch Page 7.10 / Page 7.41 19’’ DOS00401 DI-STRIP® Protector - User protection (FI) - Circuit breaker (LS) - User protection and circuit breaker (FI/LS) - Equipment protection (BladePower/PizzaPower) Page 7.11 Page 7.
SOCKET STRIPS UTE Standard Swiss Standard USA Standard Page 7.25 Page 7.36 Page 7.39 DOS00402 DOS00717 DOS00685 Page 7.26 19’’ DOS00401 Page 7.27 19’’ DOS20074 19’’ DOS20065 Page 7.28 Page 7.37 Page 7.39 Three-Phase System 19’’ DOS00686 Page 7.7 19’’ DOS20121 Page 7.38 Page 7.8 DOS00719 DOS20153a 19’’ DOS20059 Page 7.29 19’’ DOS00400 Page 7.30 19’’ DOS00397 Page 7.32 Page 7.38 DOS00720 19’’ Page 7.40 19’’ DOS00687 19’’ DOS00464 Page 7.33 DOS00399 Page 7.
SOCKET STRIPS New: Three Phase DI-STRIP ® ® TriplePower ® The TriplePower ® name reflects the performance of our latest development. The DI-STRIP® TriplePower® supplies network racks with three times the normal power. This requirement is generated by the increasingly greater packing densities and constantly rising energy requirements in racks, which are often caused by aptly named “Blade Servers” or 1 HU “Pizza Servers”, more than 40 of which can be integrated into a Knürr Miracel rack.
SOCKET STRIPS DI-STRIP® TriplePower® Strong points Cost-conscious Quick and easy mounting on the rack extrusion. Costs reduction with regard to mounting and wiring. Feed - 3x16A as standard - Ideal for implementing redundancies (e.g. 96 A) 1 DOS20131 3 DOS20126 4 DOS20129 At a glance Phase assignment colour coding (L1, L2, L3). Installation Optimum distribution over the entire rack height (standard: 23 HU and 41 HU). Technical alternatives - For 3-phase GST18 system (see page 7.19).
SOCKET STRIPS New: Three Phase – DI-STRIP ® ® BladePower ® ® PizzaPower ® A new generation of the power distribution units of the DISTRIP® range now ensures even more power: BladePower® and PizzaPower® for fail-safe power supply distribution in network racks. Increasingly greater packing densities and therefore constantly increasing energy requirements in server racks caused by blade servers or 1 HU pizza servers will now be handled electrically.
SOCKET STRIPS DI-STRIP® PizzaPower® Technical data - IEC 320 sockets (10 A) - Individually fused via thermal circuit breaker that can be reset in acc. with IEC60934.
SOCKET STRIPS DI-STRIP® Compact Standard DIN 49 440 DOS00401 DOS00262 With switch With switch DOS20020 Without switch DOS20021 With switch DOS00263 - Optionally with lit switch, 2-pole switching - 19” installation option (with length 483 mm) - 2 versions: Standard side panel or Design side panel - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Protector FI Standard DIN 49 440 DOS20065 DOS00264 Protector FI RCCB for user protection - Protection with indirect contact as error protection by switching off with inadmissible high contact voltage through contact with electrical equipment - Protection with direct contact as back-up protection - Residual operating current Ig = 10mA for alternating and intermittent fault direct current - 19” installation option (with length 483 mm) - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Protector FI / LS Standard DIN 49 440 Protector FI / LS - RCCB and circuit breaker - Provides a combination of user, overload and short circuit protection - Residual operating current Ig = 30 mA for alternating and intermittent fault directcurrent - Circuit breaker 16 A - Tripping characteristic type B, 2-pole - 19” installation option (with length 483 mm) - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Protector Emergency Stop FI / LS Standard DIN 49 440 - With 2-pole emergency stop switch for user protection - For protecting operating personnel - For manual emergency switch-off of connected equipment - Phase and neutral conductors are safely separated - Switch must be specifically unlocked to restart - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Safety Basic Standard DIN 49 440 DOS20068 DOS00306 DOS00270 With overvoltage protection With overvoltage protection With overvoltage protection - For protecting against transient overvoltages from the mains, which, for example, are caused by switching machines on and off. - With critical overvoltages the mains is separated. - Once the safety arrester has been triggered the green function display goes out. The socket strip can then no longer be used.
SOCKET STRIPS DI-STRIP® Safety Standard Standard DIN 49 440 DOS20069 DOS00307 With overvoltage protection and mains filter With overvoltage protection and mains filter DOS00271 - The “Safety Standard” models consist of a combined overvoltage protection/mains filter element. - For protecting against transient overvoltages from the mains, which, for example, are caused by switching machines on and off. - With critical overvoltages the mains is separated.
SOCKET STRIPS DI-STRIP® Master-Slave Standard DIN 49 440 DOS20070 DOS00268 With master-slave module With master-slave module - If the master equipment is switched, the slave sockets are also switched (together, with a short delay to the master). Enables easy switching on and off of several difficult to access pieces of equipment. Switching thresholds can be set from outside via potentiometer. - Note: - Power consumption of the master equipment must be constantly over the switching-on threshold.
SOCKET STRIPS DI-STRIP® Combi Standard DIN 49 440 DOS00325 With master-slave overvoltage protection and mains filter - Master-slave with overvoltage protection and mains filter - Automatic consumer switching - Combines functions of the Master-Slave (page 7.16) and the Safety Standard (page 7.15) - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® GST18 Plug System (Wieland) Compact Standard DIN 49 440 DOS20060 DOS00663 DOS20045 DOS20046 With switch - Quick and efficient plug connection system - Plug-in electro-installation in place of conventional wiring - Speed: - Due to simple plugging together of preconfigured elements - Flexibility: - Due to cable (cable length) - Efficient: - Easy exchange of socket strips, without cabling expenses - Safety: - Due to plug system, all faulty installations are excluded - Space-savin
SOCKET STRIPS DI-STRIP® Euro Socket System, IEC 320 With GST18 plug system - With 3-way Euro combinations of IEC 320 sockets - Without fuse protection Material / Finish Casing: closed sheet steel extrusion, zincplated, powder-coated texture Plastic parts: Vampamid 6 0024 VO (UL94), recyclable DOS20112 Dimensions Socket spacing: 24 mm Height: 45.5 mm Casing width: 44.
SOCKET STRIPS 3-phase in rack with GST18 Strong points DOS20147 DOS20132 DOS20142 DOS20135 1 Requirement Constantly increasing energy requirements in the rack caused by high packing densities (e.g. 1 HU Pizza Servers, Blade Servers, etc.) 2 Solution 3-phase distributor with GST18 plug system, e.g.
SOCKET STRIPS Power Supply Cable, 1-Phase Accessories for GST 18 plug system - Mains plug CEE/VII - GST18 socket (Wieland) - Cable, H05VV-F 3G 1.5 mm2 L S n F1 F2 19” Safe Colour White Order no. UP 2000 Model 04.000.040.0 1 unit 5000 04.000.041.0 1 unit DOS00467 Connection Cable Accessories for GST 18 plug system - GST 18 plug - GST 18 socket - Cable, H05VV-F 3G 1.5 mm2 L DOS00469 S n F1 F2 Colour For colour coding circuits (e.g. UPS) Model Order no.
SOCKET STRIPS DI-STRIP® Euro Socket System, IEC 320 With cable and right angle plug - Optionally with lit switch, 2-pole switching - 19” installation option - With 3-way Euro combinations of IEC 320 sockets - Cable: H05VV-F 3G 1.5 mm2 - Cable: 2.
SOCKET STRIPS DI-STRIP® Euro Socket System, IEC 320 Euro input on the side panel - With fine-wire fuse 10A - Optionally with lit switch, 2-pole switching - 19” installation option - With 3-way Euro combinations of IEC 320 sockets DOS00460 Material / Finish Casing: closed sheet steel extrusion, zincplated, powder-coated texture Plastic parts: Vampamid 6 0024 VO (UL94), recyclable Load rating 100-240 Vac Input: max. 10 A Output: max.
SOCKET STRIPS Mains Cable for Euro Socket Strip For DIN 49 440 and French/Belgian standard - Mains plug CEE/VII - Euro socket IEC 320 - Cable: HO5VV-F 3G 1 mm2 Mains voltage 250 VAC Nominal current 10 A L DOS00076 Order no. UP 2000 S n F1 F2 19” Safe Model 04.000.054.9 1 unit 6000 04.000.053.
SOCKET STRIPS DI-STRIP® Classic Standard CEE 7 V (UTE) / France DOS20018 - Optionally with lit switch, 2-pole switching - Socket rotation: 45° - Cable: H05VV-F 3G 1.5 mm2 - Moulded right angle plug Material / Finish Casing: closed sheet steel extrusion, zincplated, powder-coated texture Plastic parts: Vampamid 6 0024 VO (UL94), recyclable Internal conductor: full-length busbar, brass DOS20019 Dimensions Socket spacing: 100 mm Height: 45.5 mm Casing width: 44.4 mm (= 1 HU) Cable: 2.
SOCKET STRIPS DI-STRIP®Compact Standard CEE 7 V (UTE) / France DOS20023 With switch DOS20022 Without switch DOS20025 DOS20024 - Optionally with lit switch, 2-pole switching - 19” installation option (with length 483 mm) - 2 versions: Standard side panel or Design side panel - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Protector FI Standard CEE 7 V (UTE) / France Protector FI RCCB for user protection - Protection with indirect contact as error protection by switching off with inadmissible high contact voltage through contact with electrical equipment - Protection with direct contact as back-up protection - Residual operating current Ig = 10mA for alternating and intermittent fault direct current - 19” installation option (with length 483 mm) - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Protector FI / LS Standard CEE 7 V (UTE) / France Protector FI / LS - RCCB and circuit breaker - Provides a combination of user, overload and short circuit protection - Residual operating current Ig = 30 mA for alternating and intermittent fault directcurrent - Circuit breaker 16 A - Tripping characteristic type B, 2-pole - 19” installation option (with length 483 mm) - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Protector Emergency Stop FI / LS Standard CEE 7 V (UTE) / France DOS20029 With emergency Off switch and FI-/ LS circuit breaker - With 2-pole emergency stop switch for user protection - For protecting operating personnel - For manual emergency switch-off of connected equipment - Phase and neutral conductors are safely separated - Switch must be specifically unlocked to restart - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Safety Basic Standard CEE 7 V (UTE) / France DOS20031 DOS20032 - For protecting against transient overvoltages from the mains, which, for example, are caused by switching machines on and off. - With critical overvoltages the mains is separated. - Once the safety arrester has been triggered the green function display goes out. The socket strip can then no longer be used.
SOCKET STRIPS DI-STRIP® Safety Standard Standard CEE 7 V (UTE) / France DOS20033 DOS20034 With overvoltage protection and mains filter With overvoltage protection and mains filter - The “Safety Standard” models consist of a combined overvoltage protection/filter element. - For protecting against transient overvoltages from the mains, which, for example, are caused by switching machines on and off. - With critical overvoltages the mains is separated.
SOCKET STRIPS DI-STRIP® Master-Slave Standard CEE 7 V (UTE) / France DOS20035 With master-slave module - If the master equipment is switched, the slave sockets are also switched (together, with a short delay to the master). Enables easy switching on and off of several difficult to access pieces of equipment. Switching thresholds can be set from outside via potentiometer. - Note: - Power consumption of the master equipment must be constantly over the switching-on threshold.
SOCKET STRIPS DI-STRIP® Combi Standard CEE 7 V (UTE) / France DOS20037 DOS20036 With master-slave, overvoltage protection and mains filter - Master-slave with overvoltage protection and mains filter - Automatic consumer switching - Combines functions of the master-slave (page 7.32) and the safety standard (page 7.31) - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Compact GST 18 Plug System (Wieland) Standard CEE 7 V (UTE) / France DOS20048 DOS20047 GST 18 with switch GST 18 without switch - Quick and efficient plug connection system - Plug-in electro-installation in place of conventional wiring - Speed: - Due to simple plugging together of preconfigured elements - Flexibility: - Due to cable (cable length) - Efficient: - Easy exchange of socket strips, without cabling expenses - Safety: - Due to plug system, all faulty installations are
SOCKET STRIPS Power Supply Cable For GST18 plug system - Mains plug CEE/VII - GST18 socket (Wieland) - Cable: HO5VV-F 3G 1.5 mm2 L S n F1 F2 19” Safe Colour White Order no. UP 2000 Model 04.000.040.0 1 unit 5000 04.000.041.0 1 unit DOS00467 Connection Cable For GST18 plug system - GST18 plug - GST 18 socket - Cable: HO5VV-F 3G 1.5 mm2 L S n F1 F2 Colour White Order no. UP 1000 19” Safe Model 04.000.044.0 1 unit 5000 04.000.045.
SOCKET STRIPS DI-STRIP® Classic Standard CH SEV 1011 - With/without switch, socket spacing, 100 mm - Optionally with lit switch, 2-pole switching - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP®Compact Standard CH SEV 1011 - Optionally with lit switch, 2-pole switching - 19” installation option (with length 483 mm) - 2 Versions, standard side or design side - Socket rotation: 45º - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Protector FI/LS Standard CH SEV 1011 Protector FI / LS - RCCB and circuit breaker - Provides a combination of user, overload and short circuit protection - Residual operating current Ig = 30 mA for alternating and intermittent fault directcurrent - Circuit breaker 10 A - Tripping characteristic type B, 2-pole DOS00719 - 19” installation option (with length 483 mm) - Socket rotation: 45° - Cable: H05VV-F 3G 1.
SOCKET STRIPS DI-STRIP® Classic Standard USA NEMA5-15R - With lit switch - With overload protection 15A - Cable: SJT 14 AWG x 3C - Moulded plug, NEMA5-15P DOS00685 Material / Finish Casing: closed sheet steel extrusion, zincplated, powder-coated texture Plastic parts: Vampamid 6 0024 VO (UL94), recyclable DOS00670 Dimensions Socket spacing: 100 mm Height: 45.5 mm Casing width: 44.
SOCKET STRIPS DI-STRIP® Surge Protector Standard USA NEMA5-15R - With light switch - With overload protection 15A - With overvoltage protection - 19” installation option - Cable: SJT 14 AWG x 3C - Moulded plug, NEMA5-15P DOS00687 DOS20017 - Innova-GS - CSA NRTL/C - CB-scheme Material / Finish Casing: closed sheet steel extrusion, zincplated, powder-coated texture Plastic parts: Vampamid 6 0024 VO (UL94), recyclable With overvoltage protection Dimensions Socket spacing: 32 mm Height: 45.
SOCKET STRIPS Alarm signalling • Limit values for current and voltage can be freely set • Alarm signalling via e-mail (SMS), SNMP trap • Critical values are displayed red in the browser window • Alarm states • Fuse tripping • Alarm with an internal temperature of 80°C; automatic alarm switch-off when the temp.