Instruction Manual

WARNING
This luminaire must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
This product is not suitable for direct installation in the ground, nor in a retaining wall where the ground may
become saturated behind.
This product is not suitable for installation in or near a coastal or marine environment.
Fig. 1
Insert the sleeve into the cut-out and ensure that the mains cable is pulled through into the sleeve
Fix the sleeve to the surface using suitable screws (not provided)
Remove the terminal cover of the luminaire by unscrewing the three screws
Feed the mains cable through the gland on the rear of the terminal cover
Connect the luminaire to the mains supply ensuring the correct polarity is observed: L - Live (brown),
N - Neutral (blue)
Replace the terminal cover
Tighten the compression gland ensuring a tight seal is made
Insert the body of the luminaire into the sleeve ensuring that the side blades locate into the slotted holes in
the side of the sleeve
Switch on and check for correct operation