Instruction Manual
• Mark the location of the fixing holes and drill the holes ensuring not to infringe with any
gas/water pipes or electrical cables
• Feed the mains cable through the rubber grommet to retain IP rating, and secure the
baseplate to the surface
• Connect the luminaire to the mains supply ensuring the correct polarity is observed (see
Fig. 3): L – Live (brown), E – Earth (green/yellow), N – Neutral (blue). The earth terminal
is non-functional and only provided for convenience. The additional L’ – Slave live is able
to power additional luminaires. A maximum of 400W LED load can be controlled by the
sensor
Fig. 3
• Refasten the LED plate screw
• Reattach the diffuser by rotating clockwise
• Switch on and check for correct operation