User's Manual
Table Of Contents
- User Manual
- For
- POD System
- Safety and Regualtion Warning Notice
- 1. POD System Overview
- 2. POD system Components
- 2.1 Head-end Unit
- 2.2 Remote Unit
- 3. Equipment Installation
- 4. Cable Connection
- 5. Specification
User Manual for POD Systems Revision: 0.7
© KMW USA Inc.
1818 E. Orangethrope Ave, Fullerton, CA 92831
Tel. +1 (714) 515-1100
www.kmwcomm.com
78
- Confirm that all screws have been fastened and the unit is securely mounted to the wall.
Figure 3-7 3/5/7 band RU, PS700/800 RU – RU installed on the wall
3.3.2 Grounding
3.3.2.1 3/5/7 band RU, PS700/800 RU
Step A
Step B
Step C
Figure 3-8 3/5/7 band RU grounding
- Connect an earth-bonding cable to the grounding bolt connection provided on the outside of the remote
unit (Left-side) as shown in Figure 3-8. Do not use earth-bonding cable to connect other external devices.
loosen the two hex bolts attached to remote unit as illustrated in Figure 3-8, Step A
Connect the earth-bonding cable to remote unit as illustrated in Figure 3-8, Step B
Then, fasten all parts again by tightening the hex bolts as illustrated in Figure 3-8, Step C
- Connect the other end of the ground wire to a suitable permanent ground following local electrical code
practices.