User's Manual Part 2

User Manual for POD Systems Revision: 0.9
85
4.1.5 Cable Connection Example for MIMO configuration
POD DAS System configuration
- H-DMCU : 1ea
- H-PSU: 1ea
- H-SRU: 2ea (H-SCM, H-FAU, H-CDU)
- H-FEM: 6ea (H-FEM-L-7, H-FEM-L-C, H-FEM-L-P x2, H-FEM-L-A, H-FEM-L-W)
H-FEM-L-7, H-FEM-L-C, H-FEM-L-A, and H-FEM-L-W can support MIMO configuration by using one H-
FEM-L module because they have two paths in one module.
H-FEM-L-P supports only one path in one module. 2 H-FEM-L-P are needed to support MIMO
configuration for PCS frequency band.
- H-COM: 1ea
- H-DTM: 1ea
- H-HOM-L: 3ea
Figure 4-5 shows cable connection example for MIMO configuration.
MIMO #1
- H-FEM-L-x in H-SRU #1
- H-COM, H-DTM, and H-HOM-L in H-SRU #1
MIMO #2
- H-FEM-L-x in H-SRU #1
- H-COM, H-DTM, and H-HOM-L in H-SRU #2
Figure 4-5 Cable Connection for FDD frequency band (MIMO) support
H-SRU #1
H-SRU #2