3.2.2 Grounding
The grounding terminals are located at the rear of H-PSU, H-DMCU, and H-SRU. They must be grounded properly
before powering on the equipment.
Figure 3-10 Head-end units Grounding
3.2.3 Optic port Cleaning
We recommend that optic connector should be cleaned using a dry optical cleaning swab or tissue in a dry
environment before connecting optic cable. Also, if the expected optic loss is 1.5dB higher than the loss
reported in the Web-GUI, the optic loss should be minimized through cleaning optic connectors.(Figure 3-3)
The unused optic ports are should be covered with a protective dust cap. (Figure 3-4)
Figure 3-3 Optic Connector Cleaning (left) and Optic Port Cleaning (right)
Figure 3-4 LC/APC Optic Connector Dust Cap