Instruction Manual

Sheet 22 of 30 Sheet 22 of 30 8/17/2008
©
CONFIDENTIAL
. ALD Control Method (Refer to AISG v2.0)
Figure 8-1 shows the ALDs operation information and current status.
If you choose an ALD from the connected list, all information about the selected ALD will be displayed. And
each button executes the command compliant to AISG 2.0.
<Figure 8-1>
) Procedure (Refer to AISG v2.0 document)
Choose the ALD from the Connected List, and click Connect and Refresh button.
In case of Green LED on Link alarm and Connect LED, you can get information using
Get button.
RET: There is no alarm, you can control the antennas tilt degree using Set Tilt button. When
the Tilt operation is completed, get the current degree using Get Tilt button.
TMA: There are commands about TMA, Set TMA Mode, Get TMA Mode, Set TMA Gain,
Get TMA Gain and Get Supported Func.
) Set Assign
When Set Assign(Figure 8-1) button is clicked, window will be displayed (Figure 8-2). This window
sets ID of ALD. ID for each ALD must be entered in order to control and monitor ALDs connected to
TICU.
The communication between TICU and ALD uses the ALD ID, so you must input the unused ID.
If same ID exists on the data bus, the other ALD makes its own ID to NULL. The ID range is from 1 to
254. If the ALD is assigned to new ID, the ALD will be disconnected status.