Submittal Sheet

4
Application/Model Selection Guide
NOTE: See also Models on page 3. For details about the CO
2
model options, see Specications, CO2 Models
Only on page 6. See also the FlexStat Catalog Supplement and Selection Guide (SP-091)!
BAC-1x0063CW
BAC-1x0163CW
(+ Humidity)
BAC-1x1063CW
(+ Motion)
BAC-1x1163CW
(+ Humidity/Motion)
BAC-1x0036CW
BAC-1x0136CW
(+ Humidity)
BAC-1x1036CW
(+ Motion)
BAC-1x1136CW
(+ Humidity/Motion)
Packaged Unit (Air Handling Unit and Roof Top Unit)
1 Heat and 1 Cool
1 or 2 Heat and 1 or 2 Cool (in BAC-1xxx63 RTU Menu Only)
RTU RTU RTU RTU
1 or 2 Heat and Modulating Cool
Modulating Heat and 1 or 2 Cool
Modulating Heat and Modulating Cool (in AHU Menu Only)
AHU AHU AHU AHU
Opt. Outside Air Damper, Modulating
Opt. Outside Air Damper, 2 Position (in RTU Menu Only)
RTU RTU RTU RTU
Opt. Fan Speed Control
Opt. Dehumidification
Opt. Humidifier
Opt. Motion/Occupancy Sensor
Opt. CO2 Sensor with DCV (Demand Control Ventilation)
Opt. IP/Ethernet BACnet Communications
FCU (Fan Coil Unit)
2 Pipe, Modulating
2 Pipe, 2 Position
4 Pipe, Modulating
4 Pipe, 2 Position
Opt. Dehumidification (4 pipe only)
Opt. Humidifier (4 pipe only)
Opt. Motion/Occupancy Sensor
Opt. CO2 Sensor with DCV (Demand Control Ventilation)
Opt. IP/Ethernet BACnet Communications
HPU (Heat Pump Unit)
Opt. Outside Air Damper, Modulating
Opt. Dehumidification
Opt. Motion/Occupancy Sensor
Opt. CO2 Sensor with DCV (Demand Control Ventilation)
Opt. IP/Ethernet BACnet Communications
Model Code for BAC-1xmhra CEW:
BAC = BACnet Device
r = Number of Relay Outputs (3 or 6 standard, or 5 relays & 1 triac)
1 = Model Series
a = Number of Analog Outputs (3 or 6)
x = CO2 Sensor Type (3 or 4) or None (2) C = Real-Time Clock (RTC standard on all models)
m = Motion Sensor (1) or None (0) E= IP/Ethernet Communications Option (no E = MS/TP only)
h = Humidity Sensor (1) or None (0) W = White Color (no W = light almond)
BAC-13xxxx or BAC-14xxxx (see Note below)
Add an E to the model number: BAC-1xxxxxCEx (see Model Code)
DCV N/A for FCU applications, but CO2 levels still displayed
Add an E to the model number: BAC-1xxxxxCEx (see Model Code)
With 3-speed fan
1 or 2 compressors with auxiliary and emergency heat
BAC-13xxxx or BAC-14xxxx (see Note below)
Add an E to the model number: BAC-1xxxxxCEx (see Model Code)
NOTE: All models have a real-time clock (see Model Code). On models with a CO2 sensor, the humidity sensor is standard and
Demand Control Ventilation is only available when using an AHU, RTU, or HPU application with a modulating economizer option
enabled. For the differences between the types of CO2 sensors in the BAC-13xxxx and BAC-14xxxx, see page 6. The BAC-12xxxxx
has no CO2 sensor.
N/A
Applications and Options
3 Relays and 6 Analog Outputs6 Relays and 3 Analog Outputs
FlexStat Models