User's Manual
8
SETTING SCREEN
Main screen / Setup button
Display Settings.
Bar Graph: Select 2 types of bar graph, continuous bar or dashed bar.
Celsius / Fahrenheit: Select the unit of measure that will be
displayed on the temperature indicator.
Sound: Enables or disables the alarm sound. Note: The protections
are not disabled.
Call Sign: Displays the keyboard to put Call sign on the main screen.
Press DEL to enter your Call Sign.
Sleep: If the button is activated, the screen will turn off after 20
minutes of inactivity. Restart the screen by pressing PTT or touching
the screen..
Brightness: Slide the bar to adjust the brightness.
Antenna Memory.
Configure the three antenna outputs for each band segment.
The configuration remains in memory.
ALL TO ANT-1 button restores all bands to Antenna -1.
WARNING: Even though the power amp’s protection will
trigger a REF POWER alarm, it is always recommended to
have an antenna, or 50-ohm load connected to the
programmed output in order to avoid probable severe damage
to components.