Product Manual
Page 32 of 58
a. From the screen above, push in the MULTI-FUNCTION ADJUSTMENT/SELECTION
KNOB so the orange highlight turns into an orange outline. Then turn the MULTI-
FUNCTION ADJUSTMENT/SELECTION KNOB clockwise until the inductance icon is
outlined. Press the MULTI-FUNCTION ADJUSTMENT/SELECTION to highlight in
orange.
b. Adjust inductance Up to increase the arc cycle time, and there by increasing the fluidity
or wetting of the puddle. This will result in a wider and more even transition at the toes
of the weld.
c. Adjust inductance down to increase the short circuit frequency, and there by decreasing
puddle fluidity that may result in a narrower and faster freezing puddle.
12. Torch Trigger Options – From the screen above, push in the MULTI-FUNCTION
ADJUSTMENT/SELECTION KNOB so the orange highlight turns into an orange outline. Then
turn the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB clockwise until you see Torch
Trigger in the middle of the screen. Press the MULTI-FUNCTION ADJUSTMENT/SELECTION
KNOB to see Torch Trigger Options.
a. 2T – No Trigger Hold. Pull and hold the trigger to weld. Release the trigger to stop
welding.
b. 4T – Trigger Hold. Pull and release the trigger once to start the arc, then once again to
end the arc. The Trigger Hold allows operators flexibility to not have to hold the trigger
during long welds.
c. Spot time – Pull and Hold the trigger and the arc starts and then stops at a preset time.
Used to make multiple spot welds of consistent size and penetration.
d. Press the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to confirm your
selection.
13. Pre-Gas Time – Pre-Gas Time allows you to adjust the amount of time that gas will flow when
you pull the trigger and before the arc starts. This time should be minimal as a short burst of
gas is generally adequate before the arc starts. We recommend using the programmed pre gas
setting. However, you do have the option to adjust the pre gas time.
a. From the screen above, push in the MULTI-FUNCTION ADJUSTMENT/SELECTION
KNOB so the orange highlight turns into an orange outline. Then turn the MULTI-
FUNCTION ADJUSTMENT/SELECTION KNOB clockwise until you see the Pre-Gas
Time in the middle of the screen.