Product Manual
Page 20 of 58
Reference
Subassembly
1
Gas Bottle Valve
2
Gas Flow Gauge (Set at 20 CFH)
3
Gas Pressure Gauge
4
Regulator
5
Gas Flow Adjuster
6
Gas Hose Connection
7
Gas Cylinder
Figure 6
iv. Connect the other end of the gas hose to the gas hose connection on the
supplied regulator/flow gauge. Use a wrench to snug up the connection.
v. Before installing the regulator, it is good practice to make certain no debris is
in the gas bottle connection. Rotate the bottle so the gas connection is not
pointing toward you or any other person. Turn the valve on the gas bottle
clockwise and quickly close. This quick thrust of gas will clear any debris in the
connection. Connect the regulator to the gas bottle connection. Use a wrench
to snug up the connection.
vi. Open the Gas Bottle Valve on the cylinder of gas.
vii. Turn the Gas Flow Adjuster on the regulator so that the gas flow rate is set at
approximately 20 CFH. Make certain you are reading the correct scale on the
gauge.
NOTE: Slowly open the cylinder valve by turning it counterclockwise until the
cylinder pressure gauge registers on the first gauge of the regulator. Turn the
adjustment knob clockwise (right) slowly to increase gas flow to 20 CFH. To
reduce the gas flow, turn the adjustment counterclockwise (left). The gas valve
1
7
4
3
2
6
5