Product Manual
Page 26 of 47
iv. Choose the “√” to indicate “Yes” to using a spool gun.
v. Push in the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to
confirm your selection.
c. Preflow – You can set a time amount for how long you would like the welder to flow
gas prior to the arc starting. Some operators like to have the shielding gas covering
the area at the start of the arc to minimize arc starting issues and possible
contamination. Set in increments of .1 second (not needed for Flux Core welding).
d. Run-In WFS – You can slow down how fast the wire is traveling while the arc is
getting established. Usually this is a setting you would not adjust. However, if you
have popping at the start, using this adjustment could minimize that pop at the start.
Set as a percentage of the welding wire speed.
e. Postflow– You can set a time amount for how long you would like the welder to flow
gas after the arc. Some operators like to have the shielding gas covering the area
after the arc has terminated to minimize to avoid contamination by letting the arc pool
cool under shielding gas. Set in increments of .1 second (not needed for Flux Core
welding).
f. Trigger Hold
i. Spot time – Pull and Hold the trigger and the arc starts and then stops at a
preset time. Use to make multiple spot welds of consistent size and
penetration.
1. Counter-clockwise to decrease spot time.
2. Clockwise to increase spot time.
ii. 2T – No Trigger Hold. Pull and hold the trigger to weld. Release the trigger to
stop welding.
iii. 4T – Tap the trigger once to start the arc, tap the trigger again to end the arc.
This setting is often used for operators that have long similar welds that they
perform. The Trigger Hold allows them the flexibility to not have to hold the
trigger during long welds.
13. If you wish, you can save these weld parameters for easy access later.
a. Press the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to access the
“Press For Options” screen.
b. Turn the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB all the way
clockwise to the SAVE icon.
c. Press the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to confirm.
d. Turn the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to select Save.
e. Press the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to confirm.
f. Turn the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to select the
program number you wish to save to.
g. Press the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to confirm.
h. Review the program parameters. Then turn the MULTI-FUNCTION
ADJUSTMENT/SELECTION KNOB to the “√”.
i. Press the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to confirm.
ii. Your program is now saved and can be accessed for future use.
STICK WELDING SET-UP
1. Press the START BUTTON.
2. Turn the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB until the STICK screen is
displayed.
3. Push in the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to confirm your selection.
4. Follow the display set-up:
a. Connect the Electrode Holder to the Positive (+) Weld Output Connection.
b. Connect the Ground Cable to the Negative (-) Weld Output Connection.
5. Push in the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB.
6. Use the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to select either 6000 series
welding electrode or 7000 series welding electrode.
7. Push in the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to confirm your selection.
8. Use the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to select your electrode size.
9. Push in the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to confirm your selection.
10. Use the MULTI-FUNCTION ADJUSTMENT/SELECTION KNOB to select the thickness of the