Figure 9
3. We recommend removing the MIG torch when the Spool Gun is connected to avoid
accidental arcing. Loosen the wing nut retaining bolt and slide the MIG torch out of the front of
the machine. Disconnect the 5-Pin trigger connection on the front of the machine.
4. Carefully slide the gas connector and the weld power connection through the weld cable
access opening in the front of the machine (Figure 10).
Figure 10
5. Open the wire compartment door.
6. Connect the gas connection quick connector to the gas connector (1) on the back panel of the
wire compartment.
7. Connect the weld power connection to the bolt on the top of the MIG connector (2).
8. Connect the 5-Pin trigger connector to the 5-Pin receptacle on the front of the machine (3).
9. See step 11 of WIRE FEED WELDING SET-UP in the Operating Instructions section.
Weld Cable
Access
Opening