Step 5:  Connect drain hose
By default, the drain hose is attached to the left-
hand side of unit (when you’re facing the back 
of the unit). However, it can also be attached to 
the right-hand side. 
1.  To ensure proper drainage, attach the drain 
hose on the same side that your refrigerant 
piping exits the unit.
2.  Attach drain hose extension (purchased 
separately) to the end of drain hose.
3.  Wrap the connection point firmly with Teflon 
tape to ensure a good seal and to prevent 
leaks.
4.  For the portion of the drain hose that will 
remain indoors, wrap it with foam pipe 
insulation to prevent condensation.
5.  Remove the air filter and pour a small amount 
of water into the drain pan to make sure that 
water flows from the unit smoothly.
 NOTE ON DRAIN HOSE  
 PLACEMENT 
Make sure to arrange the drain hose 
according to  Fig. 3.5 .
  DO NOT  kink the drain hose.  
  DO NOT  create a water trap.
   DO NOT  put the end of drain hose in 
water or a container that will collect 
water.
PLUG THE UNUSED DRAIN HOLE
To prevent unwanted leaks you must plug 
the unused drain hole with the rubber plug 
provided.
CORRECT 
Make sure there are no 
kinks or dent in drain 
hose to ensure proper 
drainage.
NOT CORRECT
Kinks in the drain hose 
will create water traps.
NOT CORRECT
Do not place the end 
of the drain hose in 
water or in containers 
that collect water. This 
will prevent proper 
drainage.
NOT CORRECT
Kinks in the drain hose 
will create water traps.
Fig. 3.5
Fig. 3.6
Fig. 3.7
Fig. 3.8