3
Qty 1 Leader Hose Bracket Clip
Qty 1 Air line for remote mounting air filter
Qty 2 Nuts, bolts, and washers – (Air tank mounting hardware)
1.0 Gallon Air Tank Installation
Your 1.0 Gallon air tank comes with five 1/4” NPT port openings to allow a variety of
installation configurations in your vehicle. To insure safe and trouble-free use of your air
tank, we strongly recommend that you install the supplied drain cock and a safety
pressure relief valve. (Use contents of Package # 1 for this installation step).
IMPORTANT:
• Tank is rated for 150 PSI maximum working pressure.
• Tank is not to be used as a breathing device.
• Bleed pressure from tank before servicing or adding attachments.
• Use only attachments or tools rated for 150 PSI working pressure or less.
CAUTION! DO NOT PRESSURIZE YOUR TANK UNTIL YOU HAVE
INSTALLED
ALL NECESSARY PORT FITTINGS AND ACCESSORIES.
• Apply sealant or Teflon tape to threads of fittings prior to assembly and tighten each
part with a wrench.
• Do not over tighten, since brass threads can be stripped.
• Always release air from tank before servicing.
WARNING: FAILURE TO DRAIN TANK AND REMOVE CONDENSATION
WILL CAUSE TANK TO RUST PREMATURELY.
• To remove accumulated condensation inside the tank, use the drain cock to bleed
pressure from tank until pressure is approximately 5 PSI to 20 PSI.
• Drain water from tank by opening the drain cock drain valve and close after draining
tank.
• If drain cock valve is plugged, release all air pressure from tank, remove drain valve
and clean, then reinstall.
IMPORTANT: The drain cock should be installed at the bottom of the tank. The ports
on the tank are configured so that whether the tank is installed upright, upside-down or
sideways, there is always a port on the bottom.