Instructions
11
COAX CABLE PROPERLY WIRED:
ID
Pass
COAX CABLE WITH AN OPEN:
Open
COAX CABLE WITH A SHORT:
Short
NOTE: An open
fault will also
occur when
no remote is
connected to the
satellite end of a
video/coax cable.
WIRE MAP AND DISPLAY EXAMPLES
1. Loosen screw ion battery cover with No. 2 Phillips screwdriver.
2. Remove the battery door.
3. Disconnect the battery cable and recycle the exhausted battery.
4. Install a fresh 9-volt alkaline battery.
5. Connect battery cable to the new battery, observing polarity, and place it into battery
compartment.
6. Replace battery door and secure with a screw, taking care not to over-tighten.
WARRANTY
www.kleintools.com/warranty
CLEANING
Turn the instrument off and disconnect any cables. Clean the instrument using a damp cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when the instrument is not in use for a prolonged period of time. Do not
expose to high temperatures or humidity. After a period of storage in extreme conditions exceed-
ing the limits mentioned in the Specifications section, allow the instrument to return to normal
operating conditions before using it.
DISPOSAL/RECYCLING
Do not place the equipment and its accessories into a domestic rubbish bin. Items must
be properly disposed of in accordance with local regulations. Please see www.epa.gov or
www.erecycle.org foradditional information.
BATTERY REPLACEMENT
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069 1-800-553-4676
www.kleintools.com
CUSTOMER SERVICE
Use for cable location identification mapping and continuity testing.
Remotes display on tester asRemote ID Nos. 1-12.
UPGRADE/REPLACEMENT REMOTES
RJ45 port F-connector port
REMOTE ID NO.
PART NO.
1 VDV501-211
2 VDV501-212
3 VDV501-213
4 VDV501-214
5 VDV501-215
6 VDV501-216
7 VDV501-217
8 VDV501-218
9 VDV501-219
10 VDV501-220
11 VDV501-221
12 VDV501-222
2–6 VDV770-850
7–12 VDV770-851
TEST + MAP™ ID REMOTES (VDV501-2## SERIES)
2–6