MM5000
 
 
RANGE
 
 
 
 
 

 
4007036


  
400.0mV 0.1mV
± (0.3% + 5 digits)
4V ~ 400V 1mV ~ 0.1V
1000V 1V ± (0.8% + 10 digits)
 1000V : >10MΩ, <100pF
: >3kΩ, <200pF, up to 600V RMS

 

40Hz ~ 400Hz

400Hz ~ 2kHz
400mV 0.1mV
± (0.75% + 5 digits)
± (2.5% +10 digits)
4V ~ 400V 1mV ~ 0.1V ± (2.0% +8 digits)
1000V 1V ± (0.75% + 8 digits) ± (2.0% +8 digits)*
 1000V RMS : >10MΩ, <100pF
: >3kΩ, <200pF, up to 600V RMS
 40 to 2kHz  True RMS
*Accuracy for 400Hz ~ 1kHz range only.

  
400.0µA 0.1µA
± (1.0% + 5 digits)
2000µA 1µA
 600V RMS

  
400.0µA 0.1µA
± (1.5% + 5 digits)
2000µA 1µA
 600V RMS
 40Hz to 2kHz  True RMS

  
400Ω
˜
4MΩ 0.1Ω
˜
1kΩ ± (1.0% + 5 digits)
40MΩ 0.01MΩ ± (1.5% + 10 digits)
 600V RMS

   
600V RMS 4.0V DC Appx. 0.25mA
<
1.8V DC (typ.)

  
600V RMS Appx. 0.44V Appx. < 40Ω



CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using a
damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period
of time. Do not expose to high temperatures or humidity. After a period of
storage in extreme conditions exceeding the limits mentioned in the General
Specifications section, allow the instrument to return to normal operating
conditions before using it.

Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations
.
Prior to disposal of this product, please contact Klein Tools
for proper disposal options.


450 Bond Street
Lincolnshire, IL 60069



Rev 04/14 B 139749
 

• Press SELECT to choose AC or DC Voltage.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• See AC/DC Voltage instructions.
 
Features:


• Display shows resistance.
• Buzzer sounds if less than 40Ω.
 
Features:


Display shows:
• Forward voltage drop if forward biased.
• “O.L” if reverse biased.
 
Features:


RANGE


• Attach RED lead to “µA” input.
• Break circuit to be measured.
• Attach RED lead to "µA" input, BLACK lead to COM.
• Connect RED lead to one side of break and BLACK lead to the
other (meter in series).
• Select AC or DC current source.
Dwg Name: MM5000-139749ART Dwg No: 139749
ECO No: 016671 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A
MM5000-139749-Instructions.indd 1-4 5/5/14 10:14 AM

Summary of content (8 pages)