DESCRIPTION
The Line Splitter 10x assists in measuring the current draw of a
connected load such as an electrical device or appliance up to 15A
without splitting the device or appliances power cord. It has been
designed for use with Klein Tools clamp meters, but will also function
with many other manufacturers’ clamp meters.
GENERAL SPECIFICATIONS
Relative Humidity: < 85% non-condensing
Operating Temperature: 32° to 122°F (0°C to 50°C)
Storage Temperature: -4° to 140°F (-20°C to 60°C)
Dimensions: 4.67" x 2.28" x 1.22" (119 x 58 x 31 mm)
Nominal Voltage: 110/125V AC at 50/60Hz in 3-wire outlet
Weight: 3.2 oz. (90.7 g)
Drop Protection: 3.3 ft. (1 m)
Maximum Load Current: 15A
Measurement Correction: Clamp Meter will display 10x actual
current, eg. Actual current of 1.5A will be displayed as 15A on
clamp meter when using Line Splitter 10x.
WARNINGS
• Read, understand, and follow all warnings and instructions before
operating this device. Failure to follow instructions could result in death or
serious injury.
• Do NOT use with current loads greater than 15A (which would be displayed
as greater than 150A on a clamp meter using the Line Splitter 10x).
• Risk of electric shock and burn. Contact with live circuits could result in
death or serious injury.
• Do not use if Line Splitter 10x appears damaged in any way, if in doubt,
replace Line Splitter 10x.
• Always wear approved eye protection.
• Do NOT use Line Splitter 10x if wet.
• Intended for indoor use only.
• Always consult a qualified electrician to resolve wiring problems.