Buying Guide
Dead-Ending
Sagging Using a Dynamometer
16
COMMON OVERHEAD APPLICATIONS
See Wire Pulling Grip Warnings on the inside cover.
www.kleintools.com
1. Set up the ratchet hoist and Chicago  
Grip as shown here.
2. Ratchet the hoist until the cable is  
lined up with the dead-end fixture.
3.
After the tension is approximately where 
it will need to be after termination, 
ratchet the hoist a couple more times 
to accommodate for tension loss 
after hoist removal. Consult cable 
specifications to ensure the maximum 
cable tension is not exceeded.
4.  When finished, break the tension using the hoist handle, then use either the handle or drum knob to continue releasing the tension.
Splicing
1.  Set up ratchet hoist and Chicago  
Grips as shown here.
2.  
Connect the KN1500PEX Web Strap 
Ratchet Hoist to each grip, and  
ratchet to the desired tension to  
make the splice.
 The cable can now be spliced 
according to standard work 
procedures and material guidelines.
3. 
When finished with the splice, break 
the tension using the hoist handle, then 
use either the handle or drum knob to 
continue releasing the tension. 
1. 
Set up ratchet hoist, Chicago Grip  
and dynamometer as shown here.
2. Ratchet the hoist until the  
dynamometer displays the desired 
tension. Consult conductorspecifications 
or company procedures to determine  
the appropriate tension.
3. When finished, break the tension 
using the hoist handle, then use either 
the handle or drum knob to continue 
releasing the tension.