5. FIRE FIGHTING MEASURES
Flash Pt:
74.00 F Method Used: Setaflash Closed Cup (Rapid Setaflash)
Self-contained respiratory protection should be provided for fire fighters fighting fires in buildings or
confined areas. Storage containers exposed to fire should be kept cool with water spray to prevent
pressure build-up. Stay away from heads of containers that have been exposed to intense heat or
flame.
Fire Fighting Instructions:
Danger! Flammable. Keep away from heat, sparks, flame, and all other sources of ignition. Do not
smoke. Extinguish all flames and pilot lights, and turn off stoves, heaters, electric motors and all
other sources of ignition during use and until all vapors are gone. Beware of static electricity that
may be generated by synthetic clothing and other sources.
Flammable Properties and
Hazards:
Autoignition Pt:
No data.
Explosive Limits:
LEL: No data. UEL: No data.
1C
Use carbon dioxide, dry powder, or alcohol resistant foam.
Suitable Extinguishing Media:
Do not use straight streams of water. If water is used, use a water spray or fog.
Unsuitable Extinguishing Media:
Carbon monoxide, carbon dioxide. sulfur oxides, hydrogen sulfide
Hazardous Combustion
Products:
6. ACCIDENTAL RELEASE MEASURES
Vapors may cause flash fire or ignite explosively.
Clean up: Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind, out
of low areas, and ventilate closed spaces before entering. Shut off ignition sources; keep flares,
smoking or flames out of hazard area. Use non-sparking tools. Use proper bonding and grounding
methods for all equipment and processes. Keep out of waterways and bodies of water. Be
cautious of vapors collecting in small enclosed spaces, sewers, low lying areas, confined spaces,
etc.
Small spills: Take up with sand, earth or other noncombustible absorbent material and place in a
plastic container where applicable.
Large spills: Dike far ahead of spill for later disposal.
Waste Disposal: Dispose in accordance with applicable local, state and federal regulations.
Steps To Be Taken In Case
Material Is Released Or Spilled:
7. HANDLING AND STORAGE
Read carefully all cautions and directions on product label before use. Since empty container
retains residue, follow all label warnings even after container is empty. Dispose of empty container
according to all regulations. Do not reuse this container.
Do not use this product near any source of heat or open flame, furnace areas, pilot lights, stoves,
etc.
Do not use in small enclosed spaces, such as basements and bathrooms. Vapors can accumulate
and explode if ignited.
Precautions To Be Taken in
Handling:
Licensed to W.M. Barr and Company
GHS format