MSDS
04/16/2015Revision:
04/16/2015Printed:
Page: 4
Less Flammable Paint Thinner for SCAQMD
SAFETY DATA SHEET
03/27/2015Supersedes Revision:
7. HANDLING AND STORAGE
Read carefully all cautions and directions on product label before use. Since empty
container retains residue, follow all label warnings even after container is empty.
Dispose of empty container according to all regulations. Do not reuse this container.
Avoid breathing of vapors or mist. Avoid contact with eyes and skin.
A source of clean water should be available in or near the work area for flushing of the
eyes and skin if contact occurs.
Precautions To Be Taken in
Handling:
Keep container tightly closed when not in use. Store in a cool, dry place. Do not store
near flames or at elevated temperatures.
Protect from freezing.
Precautions To Be Taken in
Storing:
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
OSHA TWA ACGIH TWACAS # Partial Chemical Name Other Limits
No data. No data.
98-56-6 4-Chlorobenzotrifluoride
{4-Chloro-.alpha.,.alpha.,.alpha.-trifluor
otoluene}
No data.
No data. TLV: 200 mg/m3
64742-47-8 Hydrotreated light distillate (petroleum)
No data.
No data. No data.
NA Trade Secret Polymeric Ester
No data.
For use in areas with inadequate ventilation or fresh air, wear a properly maintained and
properly fitted NIOSH approved respirator for organic solvent vapors.
For OSHA controlled work places and other regular users - Use only with adequate
ventilation under engineered air control systems designed to prevent exceeding the
appropriate TLV.
A dust mask does not provide protection against vapors.
Respiratory Equipment
(Specify Type):
Safety glasses should be worn during normal handling of this material.
Where contact with the eyes or face is likely, a faceshield or chemical splash goggles
should be worn to prevent eye contact.
Eye Protection:
Wear gloves with as much resistance to the chemical ingredients as possible. Glove
materials such as nitrile rubber may provide protection. Glove selection should be based
on chemicals being used and conditions of use. Consult your glove supplier for
additional information. Gloves contaminated with product should be discarded and not
reused.
Protective Gloves:
Various application methods can dictate use of additional protective safety equipment,
such as impermeable aprons, etc., to minimize exposure.
Other Protective Clothing:
Use process enclosures, local exhaust ventilation, or other engineering controls to
control airborne levels below recommended exposure limits.
Use only with adequate ventilation to prevent buildup of vapors. Do not use in areas
where vapors can accumulate and concentrate, such as basements, bathrooms or small
enclosed areas. Whenever possible, use outdoors in an open air area. If using indoors
open all windows and doors and maintain a cross ventilation of moving fresh air across
the work area. If strong odor is noticed or you experience slight dizziness, headache,
nausea or eye-watering -- STOP -- ventilation is inadequate. Leave area immediately
Engineering Controls
(Ventilation etc.):
Licensed to W.M. Barr and Company: MIRS MSDS, (c) A V Systems, Inc.
GHS format