Operation Manual
Table Of Contents
- IMPORTANT
- Section 1 ACCESSORIES
- Section 2 PREPARATION
- Section 3 BASIC OPERATION
- Section 4 ADVANCED OPERATION
- Section 5 SCAN OPERATION
- Section 6 MENU SCREEN
- Section 7 NXDN™ OPERATION
- NXDN™ system operation
- Transmitting a call
- Receiving a call
- Roaming function (For Multi-site Trunking operation)
- Site Lock function (For Multi-site Trunking operation)
- Site Select function (For Multi-site Trunking operation)
- Incoming list
- Outgoing list
- Encryption function
- Over The Air Programming (OTAP) function
- Section 8 MDC 1200 SYSTEM OPERATION
- Section 9 BIIS 1200 SYSTEM OPERATION
- Section 10 VOICE RECORDER FUNCTIONS
- Section 11 Bluetooth® OPERATION
- Bluetooth® Wireless Technology operation
- Turning ON the Bluetooth® function
- Pairing with a headset or a data device
- Headset settings
- Accepting a pairing request from a Bluetooth® device
- Disconnecting from a Bluetooth® device
- Deleting a Bluetooth® device from the pairing list
- Resetting the installed Bluetooth® unit
- The maximum number of paired devices
- Section 12 OTHERS
- Section 13 OPTIONS

12
OTHERS
12-4
This section describes how to copy data from a
Master transceiver to a Sub transceiver using the
optional OPC-1870 zone copy cable�
NOTE: Before copying, set Transceiver Data Out to
“ON” using the CS-F52D programming software.
(Common > Security Setting > Security)
D Copying data
Step 1: Entering the Programming mode (Master)
While holding down [P1] and [F2], turn ON the
transceiver. Continue holding down [P1] and [F2] for
about 3 seconds.
• “Programming” is displayed and the transceiver enters the
Programming mode.
Step 2: Turning ON the transceiver (Sub)
Step 3: Copying data (Master)
Push [PTT] on the Master transceiver to start copying
data to the Sub transceiver.
Step 4: Complete (Master/Sub)
After copying is completed, the Master and Sub
transceivers automatically restart.
• The user can operate the Sub transceiver with the loaded
data.
D Connecting
Before copying, connect the Master and Sub
transceivers using the optional OPC-1870.
1� Turn OFF the Master and Sub transceivers.
2� Connect the two transceivers with the cable.
OPC-1870
Turn OFF Turn OFF
Copying data from a transceiver