User Guide

- 5 -
FCMG-48
4.2、Information of Gas Supply and Burner
The minimum supplied gas pressure regulator is factory set at 4”Natural
Gas W.C, and 10”L.P. Gas W.C. The external thread of product’s intake-tube
is 3/4 inches.
<Table 1>
Model
#of burners
and control
method
Gas
Species
Intake-tube
pressure
(in.W.C.)
Per BTU
B.T.U./h
Total BTU
B.T.U./h
Nozzle
No.
FCMG-24
2 pieces
Independent
control
Natural
Gas
4
30,000
60,000
#37
L.P. Gas
10
30,000
60,000
#51
FCMG-36
3 pieces
Independent
control
Natural
Gas
4
30,000
90,000
#37
L.P. Gas
10
30,000
90,000
#51
FCMG-48
4 pieces
Independent
control
Natural
Gas
4
30,000
120,000
#37
L.P. Gas
10
30,000
120,000
#51