User Guide
Table Of Contents
- 1. Safety Protection
- 2. Brief Introduction
- 3. Manufacturer's Authority and Responsibility
- 4. Parameter Specifications
- 5. Transport and Storage
- 6. Installation and Debugging
- 7. Safety Notices and Precautions
- 8. Operating Instructions
- 9. Cleaning and Maintenance
- 10.Service (authorized technicians only)
- 11. Troubleshooting
- 6 -
<Table 1>
Model
#of burners
and control
method
Gas
Species
Intake-tube
pressure
(in. W. C.)
Per BTU
B.T.U./h
Total BTU
B.T.U./h
Nozzle
No.
FCFS-40
3 pieces
Integrated
control
Natural
Gas
4
34,000
102,000
#36
L.P. Gas
10
30,000
90,000
#52
FCFS-50
4 pieces
Integrated
control
Natural
Gas
4
34,000
136,000
#36
L.P. Gas
10
30,000
120,000
#52
FCFS-75
5 pieces
Integrated
control
Natural
Gas
4
34,000
170,000
#36
L.P. Gas
10
30,000
150,000
#52
5. Transport and Storage
In the process of transportation, handle carefully and keep upright to
prevent damage of the product packing. Wrapped equipment should not be in
open air for a long time, and shall be placed in a well-ventilated and
non-corrosive gases warehouse. When equipment needs temporary storage,
rainproof measures should be taken.
6. Installation and Debugging
Any erroneous installation, adjustment, refit, overhaul or maintenance may
cause property damage or personal injury. The work shall be performed by
authorized and licensed technicians, otherwise the manufacturer has the
right not to provide warranty service;
Only be installed in accordance with the local code. If no similar standard,
you should conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the
National Gas Installation Code, CSA-B149.1, or the L.P. Gas Installation
Code, CSA-B149.2 as applicable;
The appliance individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test
pressures in excess of 1/2psi (3.45kPa).
6.1、Unpacking and Installation
Please dispose of all packaging materials and residues after unpacking;
Check the equipment. If it is damaged, please keep wrappers and receipts which